Investigating the possible effect of electrode support structure on motion artifact in wearable bioelectric signal monitoring
نویسندگان
چکیده
BACKGROUND With advances in technology and increasing demand, wearable biosignal monitoring is developing and new applications are emerging. One of the main challenges facing the widespread use of wearable monitoring systems is the motion artifact. The sources of the motion artifact lie in the skin-electrode interface. Reducing the motion and deformation at this interface should have positive effects on signal quality. In this study, we aim to investigate whether the structure supporting the electrode can be designed to reduce the motion artifact with the hypothesis that this can be achieved by stabilizing the skin deformations around the electrode. METHODS We compare four textile electrodes with different support structure designs: a soft padding larger than the electrode area, a soft padding larger than the electrode area with a novel skin deformation restricting design, a soft padding the same size as the electrode area, and a rigid support the same size as the electrode. With five subjects and two electrode locations placed over different kinds of tissue at various mounting forces, we simultaneously measured the motion artifact, a motion affected ECG, and the real-time skin-electrode impedance during the application of controlled motion to the electrodes. RESULTS The design of the electrode support structure has an effect on the generated motion artifact; good design with a skin stabilizing structure makes the electrodes physically more motion artifact resilient, directly affecting signal quality. Increasing the applied mounting force shows a positive effect up to 1,000 gr applied force. The properties of tissue under the electrode are an important factor in the generation of the motion artifact and the functioning of the electrodes. The relationship of motion artifact amplitude to the electrode movement magnitude is seen to be linear for smaller movements. For larger movements, the increase of motion generated a disproportionally larger artifact. The motion artifact and the induced impedance change were caused by the electrode motion and contained the same frequency components as the applied electrode motion pattern. CONCLUSION We found that stabilizing the skin around the electrode using an electrode structure that manages to successfully distribute the force and movement to an area beyond the borders of the electrical contact area reduces the motion artifact when compared to structures that are the same size as the electrode area.
منابع مشابه
Effect of pressure and padding on motion artifact of textile electrodes
BACKGROUND With the aging population and rising healthcare costs, wearable monitoring is gaining importance. The motion artifact affecting dry electrodes is one of the main challenges preventing the widespread use of wearable monitoring systems. In this paper we investigate the motion artifact and ways of making a textile electrode more resilient against motion artifact. Our aim is to study the...
متن کاملA motion artifact generation and assessment system for the rapid testing of surface biopotential electrodes.
Dry electrodes can reduce cost while increasing the usability and comfort of wearable monitoring systems. They are, however, susceptible to motion artifacts. The present electrode testing methods lack reliability and do not separate the factors that affect the motion artifact. In this paper, we introduce a first generation motion artifact generation and assessment system that generates the spee...
متن کاملساخت حسگر پارچهای سیگنال قلب توسط چاپ و لایه نشانی فلز مس روی پارچه پلیاستر
In the last decade, a significant progress has been made in the wearable medical devices. Scientists are extensively involved in the design of the flexible instruments equipped with garments to fulfill the daily needs and requirements. The fulfillment of this demand particularly needs a conductive fabric substrate with a high level of homogeneity, and the lowest barrier against electrical curre...
متن کاملMotion-Artifact Resistant Design of Photoplethysmograph Ring Sensor for Driver Monitoring
Through extensive literature search, it has been found that there exists strong correlation between the Mental Workload of an automobile driver with his or her physiological measurements, especially the Heart Rate Variability (HRV) measurements. In order to make a driver's HRV monitoring on the road possible, a new photoplethysmograph (PPG) Ring Sensor prototype has been devised specifically fo...
متن کاملDetermination of Nicotinic Acid by Square Wave Voltammetry on a Carbon Paste Electrode: the Crucial Effect of Electrode Composition and Analytical Conditions
The foregone studies have shown that nicotinic acid cannot produce noticeable reductive signal at carbon-based electrodes without appropriate modification of the electrode. This is an obvious reason that mercury is known as the main electrode material for electro-reduction of nicotinic acid. In this study, it has been shown that it is possible to create a remarkable reduction signal for NA at a...