Magnification Error in Digital Radiographs of the Cervical Spine Against Magnetic Resonance Imaging Measurements

نویسندگان

  • Hideki Shigematsu
  • Munehisa Koizumi
  • Masana Yoneda
  • Jin Iida
  • Takuya Oshima
  • Yasuhito Tanaka
چکیده

STUDY DESIGN Prospective study. PURPOSE The main purpose of this study was to clarify the range of magnification errors on digital plain radiographs and to determine if there is a correlation between the body mass index (BMI) of a patient and the magnification error. OVERVIEW OF LITERATURE Most clinicians currently use digital plain radiography. This new method allows one to access images and measure lengths and angles more easily than with the past technologies. In addition, conventional plain radiography has magnification errors. Although few articles mention magnification errors in regards to digital radiographs, they are known to have the same errors. METHODS We used plain digital radiography and magnetic resonance imaging (MRI) to acquire images of the cervical spine with the goal of evaluating magnification errors by measuring the anteroposterior vertebral body lengths of C2 and C5. The magnification error (ME) was then calculated: ME=(length on radiograph-length on MRI)/length on MRI ×100 (%). The correlation coefficient between the magnification error and BMI was obtained using Pearson's correlation analysis. RESULTS Average magnification errors in C2 and C5 were approximately 18.5%±5.4% (range, 0%-30%) and 20.7%±6.3% (range, 1%-32%). There was no positive correlation between BMI and the magnification error. CONCLUSIONS There were magnification errors on the digital plain radiographs, and they were different in each case. Maximum magnification error differences were 30% (C2) and 31% (C5). Based on these finding, clinicians must pay attention to magnification errors when measuring lengths using digital plain radiography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

دقت رادیوگرافی پانورامیک و توموگرافی خطی در تعیین محل کانال مندیبولار

Background and Aim: Accurate bone measurements are essential to determine the optimal size and length of dental implants. The magnification factor of radiographic images may vary with the imaging technique used. The purpose of this study was to compare the accuracy of linear tomography and panoramic radiography in vertical measurements, as well as the accuracy of linear tomography in mandibular...

متن کامل

Correlation between magnetic resonance imaging and radiographic measurement of cervical spine in cervical myelopathic patients.

PURPOSE To correlate the radiographic measurement, cord diameter shown on magnetic resonance imaging (MRI), and clinical hand sign of cervical myelopathic patients. METHODS Patients with clinical cervical myelopathy who had had MRI in Kwong Wah Hospital between January 2001 and December 2002 were enlisted. Their cervical spine radiographs and clinical records were reviewed. RESULTS Of 36 pa...

متن کامل

Image Quality and Entrance Surface Dose Evaluation of Lateral Cervical Spine: A Study Using Grid and Non-Grid Techniques

Introduction: The purpose of this study is to investigate the effects of grid and non-grid techniques in the lateral cervical spine radiography on image quality and entrance surface dose (ESD). Although image quality and radiation doses have been studied by researchers, there is still a dearth of information on image quality and patient dose with different techniques. Material and Methods: The...

متن کامل

Fabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System

  Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...

متن کامل

Determining the sagittal dimensions of the canal of the cervical spine. The reliability of ratios of anatomical measurements.

The ratio of the sagittal diameter of the cervical canal to the corresponding diameter of the vertebral body has been described as a reliable means for assessing stenosis of the canal and detecting those at risk of cervical neuropraxia. The use of ratio techniques has the advantage of avoiding variation in magnification when direct measurements are made from plain radiographs. We examined the r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2013