Thoracic Aortic Injury: Embolization of the Tenth Intercostal Artery and Endovascular Treatment in a Young Woman after Posterior Spinal Instrumentation

نویسندگان

  • Konstantinos Lagios
  • Georgios Karaolanis
  • Theodossios Perdikides
  • Theodoros Bazinas
  • Nikolaos Kouris
  • Spiros Sfikas
  • Odysseas Paxinos
چکیده

Iatrogenic aortic injuries are rare and well-recognized complications of a variety of procedures, including spinal surgery. The placement of pedicle screws is sometimes associated with devastating consequences. Aortic perforation with rapid hematoma formation and delayed aortic trauma leading to pseudoaneurysm formation have been described in the literature. A case describing a significant time interval between iatrogenic aortic injury and diagnosis in the absence of pseudoaneurysm formation is described in this paper and, according to our knowledge, is unique in the literature. The aortic injury was successfully treated, selecting the appropriate graft and, as a consequence, normal spinal cord blood flow was achieved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Late lumen loss in thoracic aortic end graft after endovascular procedure of a traumatic pseudoaneurysm

We report the case of a 23-year-old woman who died due to endograft stenosis 20 months after thoracic endovascular aortic repair. The patient presented with the pseudocoarctation syndrome. Although angioplasty of stenosis endograft was successfully performed, severe metabolic complications were lethal.

متن کامل

An endovascular treatment of a thoracic aortic injury caused by a misplaced pedicle screw: Case report and review of the literature.

Aortic injuries are devastating complications after spinal surgery. We here would like to share our experience with a successful endovascular treatment of an iatrogenic thoracic aortic injury caused by misplaced pedicle screw after spinal surgery. A patient underwent posterior spinal surgery for L1 burst fracture was transferred to our department for instrumentation removal. An iatrogenic thora...

متن کامل

Unstable thoracic spine fracture with aortic encroachment: A potentially fatal association and a suggested treatment

BACKGROUND The coexistence of an unstable spinal fracture with a pending aortic lesion is potentially catastrophic and a therapeutic challenge as to timing of treatment, assigning priorities and selecting the best approach. CASE REPORT A 41 year-old healthy male victim of bike accident. Imaging revealed a fracture of 6th and 7th thoracic vertebrae with a bone fragment in close proximity to th...

متن کامل

Hybrid Thoracic Endovascular Aortic Repair for Intercostal Patch Aneurysm after Thoracoabdominal Aortic Replacement.

We report a case of hybrid thoracic endovascular aortic repair for intercostal patch aneurysm after thoracoabdominal aortic replacement. Eighteen years ago, a 63-year-old woman with Marfan syndrome had undergone thoracoabdominal aortic replacement with reimplantation of the intercostal artery in an island fashion. Follow-up computed tomography (CT) revealed a remaining intercostal patch aneurys...

متن کامل

THERAPEUTIC EMBOLIZATION OF BRONCHIAL ARTERY FOR MASSIVE HEMOPTYSIS

34 bronchial and 13 intercostal arteries were selectively embolized in 27 patients. The most frequent predisposing factor was either active or residual pulmonary tuberculosis. The procedure was performed with Urografin as the contrast agent, cobra shaped or headhunter catheters, and gelfoam (no. 18) or Ivalon (no. 9) particles. The most common anatomic pattern was a common bonchial artery ...