Automated molecular formula determination by tandem mass spectrometry (MS/MS).

نویسندگان

  • Suwatchai Jarussophon
  • Stephane Acoca
  • Jin-Ming Gao
  • Christophe Deprez
  • Taira Kiyota
  • Cristina Draghici
  • Enrico Purisima
  • Yasuo Konishi
چکیده

Automated software was developed to analyze the molecular formula of organic molecules and peptides based on high-resolution MS/MS spectroscopic data. The software was validated with 96 compounds including a few small peptides in the mass range of 138-1569 Da containing the elements carbon, hydrogen, nitrogen and oxygen. A Micromass Waters Q-TOF Ultima Global mass spectrometer was used to measure the molecular masses of precursor and fragment ions. Our software assigned correct molecular formulas for 91 compounds, incorrect molecular formulas for 3 compounds, and no molecular formula for 2 compounds. The obtained 95% success rate indicates high reliability of the software. The mass accuracy of the precursor ion and the fragment ions, which is critical for the success of the analysis, was high, i.e. the accuracy and the precision of 850 data were 0.0012 Da and 0.0016 Da, respectively. For the precursor and fragment ions below 500 Da, 60% and 90% of the data showed accuracy within < or = 0.001 Da and < or = 0.002 Da, respectively. The precursor and fragment ions above 500 Da showed slightly lower accuracy, i.e. 40% and 70% of them showed accuracy within < or = 0.001 Da and < or = 0.002 Da, respectively. The molecular formulas of the precursor and the fragments were further used to analyze possible mass spectrometric fragmentation pathways, which would be a powerful tool in structural analysis and identification of small molecules. The method is valuable in the rapid screening and identification of small molecules such as the dereplication of natural products, characterization of drug metabolites, and identification of small peptide fragments in proteomics. The analysis was also extended to compounds that contain a chlorine or bromine atom.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ms/ms Data Improves Automated Determination of Molecular Formulas by Mass Spectrometry

In theory, the molecular formula of an unknown compound can be calculated from its exact molecular mass. However, even with highly accurate modern mass spectrometers with an accuracy of 1 ppm or lower, it is generally not possible to determine the molecular formula uniquely from measurements. Intensities of isotopic peaks are typically used as additional information to narrow down possible form...

متن کامل

Determination of total folates in infant formula and adult nutritionals by trienzyme extraction and UPLC-MS/MS Quantitation: First Action 2011.06.

The method for "Determination of Total Folates in Infant Formula and Adult Nutritionals by Trienzyme Extraction and UPLC-MS/MS Quantitation" was submitted to the Folate Working Group for consideration for adoption as Official First Action by AOAC INTERNATIONAL. This method uses ultra performance liquid chromatography/tandem mass spectrometry (UPLC-MS/MS) to determine the total folates in infant...

متن کامل

A quick and Sensitive Liquid Chromatography–tandem Mass Spectrometry (LC-MS) Method for the Determination of Enalapril and Enalaprilat in Human Plasma: Application to a Bioequivalence Study

A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method for the estimation of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode was operated under the multiple-reaction monitoring mode. Sample pretreatment involved in a one-step protein precipitat...

متن کامل

Liquid chromatography–tandem mass spectrometry (LC-MS) method for the assignment of enalapril and enalaprilat in human plasma

A rapid and sensitive liquid chromatography&ndash;tandem mass spectrometry (LC-MS) method was developed for the determination of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode which was operated under the multiple-reaction monitoring mode. Sample pretreatment was involved...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 134 4  شماره 

صفحات  -

تاریخ انتشار 2009