Design and performance of a small-animal imaging system using synthetic collimation.
نویسندگان
چکیده
This work outlines the design and construction of a single-photon emission computed tomography imaging system based on the concept of synthetic collimation. A focused multi-pinhole collimator is constructed using rapid-prototyping and casting techniques. The collimator projects the centre of the field of view (FOV) through 46 pinholes when the detector is adjacent to the collimator, with the number reducing towards the edge of the FOV. The detector is then moved further from the collimator to increase the magnification of the system. The object distance remains constant, and each new detector distance is a new system configuration. The level of overlap of the pinhole projections increases as the system magnification increases, but the number of projections subtended by the detector is reduced. There is no rotation in the system; a single tomographic angle is used in each system configuration. Image reconstruction is performed using maximum-likelihood expectation-maximization and an experimentally measured system matrix. The system matrix is measured for each configuration on a coarse grid, using a point source. The pinholes are individually identified and tracked, and a Gaussian fit is made to each projection. The coefficients of these fits are used to interpolate the system matrix. The system is validated experimentally with a hot-rod phantom. The Fourier crosstalk matrix is also measured to provide an estimate of the average spatial resolution along each axis over the entire FOV. The 3D synthetic-collimator image is formed by estimating the activity distribution within the FOV and summing the activities in the voxels along the axis perpendicular to the collimator face.
منابع مشابه
Evaluation of MLC Thickness and Composite Effects on Collimation Parameters using EGSnrc and IAEA Phase Space Data
Background: Recently, multileaf collimators (MLC) have become an important part of any LINAC collimation system because they reduce the treatment planning time and improve the conformity. Important factors that affect MLCs collimation performance are leaves material composition and their thickness.Objective: In this study, we investigate main dosimetric parameters of a typical MLC includi...
متن کاملEvaluation of the performance of parallel-hole collimator for high resolution small animal SPECT: A Monte Carlo study
Introduction: Image quality and accuracy of in vivo activity quantification in SPECT are affected by collimator penetration and scatter components, especially in high energy imaging. These phenomena highly depend on the collimator characteristic and photon energy. The presence of penetrated and scattered photons from collimator in SPECT images degrades spatial resolution, contr...
متن کاملDesign of Small Animal Computed Tomography Imaging for in vitro and in vivo Studies
Introduction: Mini Computed Tomography (mini-CT) was suggested in biomedical research to investigate tissues and small animals. We present designed and built a mini x-ray computed tomography (mini-CT) for small animals as well as industrial component imaging. Materials and Methods: The system used in this study includes a X-ray tube 20kV to 160kV and a flat pa...
متن کاملBremsstrahlung imaging from the liver using the Monte Carlo simulation
Introduction: Most beta and gamma radiation radioisotopes used for treatment are not suitable for imaging. The bremsstrahlung images on a conventional gamma camera helped to localize the radionuclide within and outside of the lesion. Secondary scattering of gamma rays of higher energy and bremsstrahlung causes contamination in the energy window and reducing the contrast and resolution of the im...
متن کاملElectro-Optical Design of Imaging Payload for a Remote Sensing Satellite
Remote sensing using small spacecraft arising from multi-objective economic activity problems is getting more and more developed. These satellites require very accurate pointing to specific locations of interest, with high reliability and small latency. The space borne imaging systems always attempted to achieve the highest ground resolution possible with the available technology at the given t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 58 10 شماره
صفحات -
تاریخ انتشار 2013