Comparison of the Efficiency of Dynamic Phasor Models Derived from ABC and DQ0 Reference Frame in Power System Dynamic Simulations

نویسنده

  • Turhan Demiray
چکیده

Generally model equations of power system components such as transmission lines, transformers and loads etc. are given in the ABC reference frame. But for components with rotating masses such as synchronous machines, induction motors etc., the DQ0 reference frame is usually preferred. In this paper dynamic phasor models of synchronous machines and transmission lines will be derived in ABC and DQ0 reference frame. An efficiency and accuracy comparison in simulations will be made with SMIB test system between these differently derived dynamic phasor models.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simulation of Power Systems Dynamics using Dynamic Phasor Models

SUMMARY Dynamic phasor modeling technique is mostly applied on power electronics devices. In this paper, application of the dynamic phasor modeling technique is extended to other major power system components. Starting from the detailed time-domain models, the dynamic phasor models for these components are derived and implemented. Further, an efficiency and accuracy comparison of the dynamic ph...

متن کامل

Neuro-Fuzzy Based Algorithm for Online Dynamic Voltage Stability Status Prediction Using Wide-Area Phasor Measurements

In this paper, a novel neuro-fuzzy based method combined with a feature selection technique is proposed for online dynamic voltage stability status prediction of power system. This technique uses synchronized phasors measured by phasor measurement units (PMUs) in a wide-area measurement system. In order to minimize the number of neuro-fuzzy inputs, training time and complication of neuro-fuzzy ...

متن کامل

The Effect of Analysis Methods on the Response of Steel Dual-System Frame Buildings for Seismic Retrofitting

In the present paper, the focus is on the evaluation of steel dual-system frame buildings using four main types of structural analysis (Linear Static, Linear Dynamic, Nonlinear Static and Nonlinear Dynamic Analyses) with regard to "Seismic Rehabilitation Code for Existing Buildings in Iran" (based on FEMA 273 and 356) where the first two authors of the article tend to follow the previous work (...

متن کامل

Optimization of numerical integration methods for the simulation of dynamic phasor models in power systems

This paper proposes the use of frequency matched linear numerical integration techniques for the simulation of systems modelled by the dynamic phasors approach (DPA). Such methods show an increased accuracy and computational efficiency around the matched frequency. Such frequency matched methods are derived by analyzing the local truncation error in the frequency domain and determining the coef...

متن کامل

Effects of Brace-viscous Damper System on the Dynamic Response of Steel Frames

In this study, the effects of three different viscous damper configurations, chevron, diagonal and toggle, as well as brace stiffness on the performance of brace-viscous damper system in various steel frams under different earthquake records were investigated. A finite element software, ANSYS, is exploited to develop the numerical models. To verify the numerical simulations, their results were ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006