Defibrillation threshold testing does not predict clinical outcomes during long-term follow-up: a meta-analysis.
نویسندگان
چکیده
BACKGROUND Defibrillation threshold (DFT) testing at the time of implantable cardioverter defibrillator (ICD) implantation is widely used in clinical practice, but reliable data supporting its routine use are lacking. We undertook a meta-analysis to evaluate the efficacy of DFT testing compared to no DFT testing at the time of ICD implantation. METHODS We searched the MEDLINE and EMBASE databases for studies evaluating the effect of DFT testing on total mortality and ventricular arrhythmias during follow-up. Risk ratios (RR) with 95% confidence intervals (CI) were calculated using random effects modeling. RESULTS Eight studies involving 5,020 patients (3,068 undergoing DFT and 1,952 not undergoing DFT) were included. Of those, only one study was randomized. Reasons for not performing DFT included patient characteristics (four studies), center's standard practice (three studies), or randomization (one study). Median follow-up was 24 months. Overall, the quality of the included studies was rather poor. On the basis of the pooled estimate across the studies, DFT testing did not reduce total mortality or ventricular arrhythmias at follow-up (RR = 0.94, 95% CI 0.74-1.21; P = 0.65 and RR = 1.19, 95% CI 0.85-1.68; P = 0.30, respectively). No individual study had a major impact on the estimated RR or the statistical significance based on a sensitivity analysis. CONCLUSION Recognizing the limited quality of current studies in the area of DFT testing and outcomes, available data suggest that DFT testing at the time of ICD implantation does not appear to predict total mortality and ventricular arrhythmias during follow-up. Large randomized controlled trials, adequately powered to detect clinical outcomes, are warranted.
منابع مشابه
Defibrillation threshold testing fails to show clinical benefit during long-term follow-up of patients undergoing cardiac resynchronization therapy defibrillator implantation.
BACKGROUND The utility of defibrillation threshold testing in patients undergoing implantable cardioverter-defibrillator (ICD) implantation is controversial. Higher defibrillation thresholds have been noted in patients undergoing implantation of cardiac resynchronization therapy defibrillators (CRT-D). Since the risks and potential benefits of testing may be higher in this population, we sought...
متن کاملClinical efficacy of local injection therapies for lateral epicondylitis: A systematic review and network meta-analysis
Background: We aimed to compare the efficacy of local injection therapies for lateral epicondylitis in a Bayesian framework. Methods: We searched the Embase, PubMed, Cochrane Central Register of Controlled Trials, Web of Science, Scopus, and ProQuest, for randomized controlled trials published from inception to February 2021 in any languages. The injection therapies included corticosteroids (C...
متن کاملLong-term evaluation of the ventricular defibrillation energy requirement.
INTRODUCTION Defibrillation energy requirements in patients with nonthoracotomy defibrillators may increase within several months after implantation. However, the stability of the defibrillation energy requirement beyond 1 year has not been reported. The purpose of this study was to characterize the defibrillation energy requirement during 2 years of clinical follow-up. METHODS AND RESULTS Th...
متن کاملSubcutaneous Implantable Cardioverter Defibrillators Implantation Without Defibrillation Threshold Testing: A Single Center Experience
Background Subcutaneous implantable cardioverter defibrillator (S-ICD) system has been proven to be an effective therapy for prevention of sudden cardiac death (SCD) in selected patients. Although the Shockless IMPLant Evaluation (SIMPLE) trial has shown that defibrillation threshold (DFT) testing is not necessary for transvenous ICD (TV-ICD) systems, it is still recommended for S-ICD systems. ...
متن کاملSystematic Review of Defibrillation Threshold Testing at De Novo Implantation.
BACKGROUND Recent results from the largest multicenter randomized trial (Shockless IMPLant Evaluation [SIMPLE]) on defibrillation threshold (DFT) testing suggest that while shock testing seems safe, it does not reduce the risk of failed shocks or prolong survival. A contemporary systematic review of DFT versus no-DFT testing at the time of implantable cardioverter-defibrillator implantation was...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Pacing and clinical electrophysiology : PACE
دوره 36 11 شماره
صفحات -
تاریخ انتشار 2013