Mixed reality temporal bone surgical dissector: mechanical design

نویسندگان

  • Jordan Brent Hochman
  • Nariman Sepehri
  • Vivek Rampersad
  • Jay Kraut
  • Milad Khazraee
  • Justyn Pisa
  • Bertram Unger
چکیده

OBJECTIVE The Development of a Novel Mixed Reality (MR) Simulation. An evolving training environment emphasizes the importance of simulation. Current haptic temporal bone simulators have difficulty representing realistic contact forces and while 3D printed models convincingly represent vibrational properties of bone, they cannot reproduce soft tissue. This paper introduces a mixed reality model, where the effective elements of both simulations are combined; haptic rendering of soft tissue directly interacts with a printed bone model. This paper addresses one aspect in a series of challenges, specifically the mechanical merger of a haptic device with an otic drill. This further necessitates gravity cancelation of the work assembly gripper mechanism. In this system, the haptic end-effector is replaced by a high-speed drill and the virtual contact forces need to be repositioned to the drill tip from the mid wand. Previous publications detail generation of both the requisite printed and haptic simulations. METHOD Custom software was developed to reposition the haptic interaction point to the drill tip. A custom fitting, to hold the otic drill, was developed and its weight was offset using the haptic device. The robustness of the system to disturbances and its stable performance during drilling were tested. The experiments were performed on a mixed reality model consisting of two drillable rapid-prototyped layers separated by a free-space. Within the free-space, a linear virtual force model is applied to simulate drill contact with soft tissue. RESULTS Testing illustrated the effectiveness of gravity cancellation. Additionally, the system exhibited excellent performance given random inputs and during the drill's passage between real and virtual components of the model. No issues with registration at model boundaries were encountered. CONCLUSION These tests provide a proof of concept for the initial stages in the development of a novel mixed-reality temporal bone simulator.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Endoscopic access to the infratemporal fossa and skull base: a cadaveric study.

OBJECTIVES To demonstrate that the regions of the infratemporal fossa and skull base at the level of the foramen ovale can be visualized endoscopically and that structures can be manipulated within these regions using endoscopic instruments. METHODS Cadaveric dissection of 3 human cadavers using an endoscopic optical dissector. In all, 6 endoscopic infratemporal fossa and skull base approache...

متن کامل

UltraSonic Bone Dissector: Applications in Spine Surgery and Surgical Technique Guide

The Misonix BoneScalpel is a novel ultrasonic surgical device that cuts bone and spares soft tissues. This relative selectivity for bone ablation makes BoneScalpel ideally suited for spine applications where bone must be cut adjacent to dura and neural structures. Extensive clinical experience with this device confirms its safety and efficacy in spine surgery. The aim of this report is to descr...

متن کامل

Assessment of skills using a virtual reality temporal bone surgery simulator

Surgery on the temporal bone is technically challenging due to its complex anatomy. Precise anatomical dissection of the human temporal bone is essential and is fundamental for middle ear surgery. We assessed the possible application of a virtual reality temporal bone surgery simulator to the education of ear surgeons. Seventeen ENT physicians with different levels of surgical training and 20 m...

متن کامل

Ultrasonic total uncinectomy: a novel technique for complete anterior decompression of cervical nerve roots.

BACKGROUND In standard anterior cervical diskectomy, complete resection of the uncinate process is not commonly attempted because of the risk of injury to the vertebral artery. This may result in incomplete decompression of the nerve root when there is severe osseous foraminal stenosis. OBJECTIVE To demonstrate the feasibility of total uncinectomy with an ultrasonic bone dissector in patients...

متن کامل

Diagnostic value of CT and MRI of Temporal Bone in Cochlear Implantation Candidates

Background Cochlear implantation is an approved treatment which can be used to treat severe to profound hearing loss. Imaging before cochlear implant surgery is very important in decision making and assessing the temporal bone anatomy for surgery. We aimed to assess the diagnostic value of high resolution CT scan (HRCT), and MRI of temporal bone in candidate pati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 43  شماره 

صفحات  -

تاریخ انتشار 2014