The effect of membrane biocompatibility on plasma beta 2-microglobulin levels in chronic hemodialysis patients.

نویسندگان

  • R M Hakim
  • R L Wingard
  • L Husni
  • R A Parker
  • T F Parker
چکیده

Several studies have shown that patients who have been dialyzed with high-flux biocompatible membranes have a lower plasma level of beta 2-microglobulin and a lower incidence of amyloid disease compared with patients who have been dialyzed with low-flux bioincompatible membranes. However, because high-flux membranes are associated with significant dialytic removal of beta 2-microglobulin, the specific role of membrane biocompatibility in influencing the rate of increase of beta 2-microglobulin has not been previously determined. This study investigated the effect of biocompatibility on the rate of increase of plasma levels of beta 2-microglobulin in 159 new hemodialysis patients from 13 dialysis centers (ten centers affiliated with Dallas Nephrology Associates and three with Vanderbilt University Medical Center) by using two low-flux membranes with widely different biocompatibilities. These patients were prospectively randomized to be dialyzed with either a low-flux biocompatible membrane or a low-flux bioincompatible membrane. Plasma beta 2-microglobulin levels were measured at 0, 3, 6, 9, 12, and 18 months. Sixty-six patients completed the 18-month study. Plasma beta 2-microglobulin increased in all patients; however, the increase was not significantly different from baseline at any time point in the group that used the biocompatible membrane. In this group, beta 2-microglobulin increased from (mean +/- SD) 27.8 +/- 14.8 mg/L to 34.0 +/- 10.0 mg/L at 18 months (P = not significant), and the mean increase at 18 months was 2.6 +/- 14.7 mg/L. In contrast, the increase in plasma beta 2-microglobulin level in the bioincompatible membrane group became significant in Month 6 when the levels had increased from a baseline of 24.8 +/- 9.6 mg/L to 29.5 +/- 12.2 mg/L (P < 0.001); these increases continued to be significant until Month 18, when serum beta 2-microglobulin reached 36.8 +/- 13.9 mg/L with an average increase of 11.8 +/- 11.2 mg/L (P < 0.0001). The higher rate of plasma B2-microglobulin increase in the group that had been dialyzed with the bioincompatible membrane was also evident when only patients who had completed the study were analyzed. There were no significant differences in the actual level of beta 2-microglobulin or in residual renal function between the two groups during the 18 months of the study. It was concluded that over a period of 18 months, the use of biocompatible membranes, even in the low-flux configuration, is associated with a significantly slower increase in plasma beta 2-microglobulin, independent of the influence of residual renal function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ارتباط میان فاکتور التهابی CRP با بتا-2 میکروگلبولین در بیماران همودیالیزی مزمن تحت دیالیز با High-flux membrane

Background: One of the toxins accumulated in the body of hemodialysis patients is beta-2 microglobulin which is caused and increased by various factors. The one of this factors that can affect beta-2 macroglobulin is of membrane type that using in hemodialysis. In the present study, we examined the impact of C-reactive protein (CRP) as an inflammatory factor on beta-2 microglobulin in high-flux...

متن کامل

Biocompatibility of hemodialysis membranes.

Exposure of blood to hemodialysis membranes results in numerous interactions between the blood elements and the membrane. Transformation and adsorption of plasma proteins (such as complement) and activation of blood cells (such as neutrophils and monocytes) have been studied most extensively by nephrologists in recent years. There is no consensus on the definition of biocompatibility for dialyz...

متن کامل

An Investigation of the Relationship between Beta-2 Microglobulin (β2M) and Inflammatory Factors (Serum Levels of CRP and Albumin) and High Density Lipoproteins (HDL) in Hemodialysis Patients

Background and Objective: Beta-2 Microglobulin (&beta;2M) is a middle molecular weight uremic toxin. Lack of &beta;2M removal leads to &beta;2M accumulation and amyloidosis in hemodialysis patients. The present research aims to determine the relationship between &beta;2M and inflammatory factors, such as C-reactive protein (CRP), albumin, and high-density lipoprotein (HDL) in hemodialysis patie...

متن کامل

Advances in Polysulfone-Based Membranes for Hemodialysis

The polysulfone-based membrane has been used in hemodialysis (HD) and it is continuously developed to maintain its sustainability on the subject of biocompatibility. During the polysulfone-based membrane development, several parameters should be considered to improve the membrane performances, such as excellent biocompatibility, appropriate ultrafiltration rate, and effective clearance of the t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Society of Nephrology : JASN

دوره 7 3  شماره 

صفحات  -

تاریخ انتشار 1996