BACKGROUND Volume status assessment is an important aspect of patient management in the surgical intensive care unit (SICU). Echocardiologist-performed measurement of IVC collapsibility index (IVC-CI) provides useful information about filling pressures, but is limited by its portability, cost, and availability. Intensivist-performed bedside ultrasonography (INBU) examinations have the potential to overcome these impediments. We used INBU to evaluate hemodynamic status of SICU patients, focusing on correlations between IVC-CI and CVP. STUDY DESIGN Prospective evaluation of hemodynamic status was conducted on a convenience sample of SICU patients with a brief (3 to 10 minutes) INBU examination. INBU examinations were performed by noncardiologists after 3 hours of didactics in interpreting and acquiring two-dimensional and M-mode images, and > or =25 proctored examinations. IVC-CI measurements were compared with invasive CVP values. RESULTS Of 124 enrolled patients, 101 had CVP catheters (55 men, mean age 58.3 years, 44.6% intubated). Of these, 18 patients had uninterpretable INBU examinations, leaving 83 patients with both CVP monitoring devices and INBU IVC evaluations. Patients in three IVC-CI ranges (<0.20, 0.20 to 0.60, and >0.60) demonstrated significant decrease in mean CVP as IVC-CI increased (p = 0.023). Although <5% of patients with IVC-CI <0.20 had CVP <7 mmHg, >40% of this group had a CVP >12 mmHg. Conversely, >60% of patients with IVC-CI >0.6 had CVP <7 mmHg. CONCLUSIONS Measurements of IVC-CI by INBU can provide a useful guide to noninvasive volume status assessment in SICU patients. IVC-CI appears to correlate best with CVP in the setting of low (<0.20) and high (>0.60) collapsibility ranges. Additional studies are needed to confirm and expand on findings of this study.
منابع مشابه
اندازه گیری قطر قدامی – خلفی ورید اجوف تحتانی توسط سونوگرافی به عنوان یک روش غیر تهاجمی در تخمین میزان فشار ورید مرکزی در بیماران بستری در بخش مراقبت های ویژه
Introduction:The assessment of intravascular volume in severely traumatized patients or patients admitted in ICU is very essential. At present the accurate method for estimating the intravascular volume requirement is by measuring the CVP which is an invasive method. The measurement of IVC diameter by ultrasound has been suggested as an easily available and simple method for measuring the intra...
متن کاملCorrelation of Ultrasonographic Measurement of Inferior Vena Cava Collapsibility Index with Central Venous Pressure in Diagnosis and Management of Neonatal Shock
Background: Neonatal intensive care unit (NICU)Conventionally, Central Venous Pressure (CVP) monitoring has beenused by intensivists to measure intravascular volume. However, it is an invasive procedure resulting in many complications. Non-invasive ultrasonographic measurement of inferior vena cava collapsibility index (IVC-CI) is a promising alternative. Therefore, this study wasconducte...
متن کاملCorrelation of IVC Diameter and Collapsibility Index With Central Venous Pressure in the Assessment of Intravascular Volume in Critically Ill Patients
OBJECTIVE The objective of our study is to assess the correlation between inferior vena cava (IVC) diameters, central venous pressure (CVP) and the IVC collapsibility index for estimating the volume status in critically ill patients. METHODS This cross-sectional study used the convenient sampling of 100 adult medical intensive care unit (ICU) patients for a period of three months. Patients ≥ ...
متن کاملA Non-invasive Method for Assessment of Intravascular Fluid Status: Inferior Vena Cava Diameters and Collapsibility Index
OBJECTIVE To evaluate the correlation between central venous pressure (CVP) and inferior vena cava (IVC) diameters measured by ultrasonography (Ultrasound) in critically ill patients. METHODS Intubated critically ill patients were enrolled. The CVP values were measured using a U-tube manometer and were compared to the IVC diameters and collapsibility index, which were measured by bedside Ultr...
متن کاملThe efficacy of sonographic measurement of inferior vena cava diameter as an estimate of central venous pressure
BACKGROUND Central venous pressure (CVP) and right atrial pressure (RAP) are important parameters in the complete hemodynamic assessment of a patient. Sonographic measurement of the inferior vena cava (IVC) diameter is a non-invasive method of estimating these parameters, but there are limited data summarizing its diagnostic accuracy across multiple studies. We performed a comprehensive review ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Surgeons
دوره 209 1 شماره
صفحات -
تاریخ انتشار 2009