Atp-bioluminescence Assay as an Alternative for Hygiene-monitoring Procedures of Stainless Steel Milk Contact Surfaces

نویسندگان

  • Patrícia Dolabela Costa
  • Nélio José Andrade
  • Sebastião César Cardoso Brandão
  • Frederico José Vieira Passos
  • Nilda de Fátima Ferreira Soares
چکیده

ATP-bioluminescence assay was used to evaluate the cleaning and sanitizing procedures of stainless steel milk contact surfaces. Surfaces of a raw milk transportation tank, a raw milk cooling storage tank, an equalization pasteurizing tank, a pasteurized milk storage tank and a pasteurized milk packaging tank, as well as a milk centrifuge were evaluated. The Relative Light Unit (RLU) using a commercial luminometer and mesophilic aerobic counts (CFU.cm) on surfaces were determined. There were no significant differences (p>0.05) in RLU on the assessed surfaces before and after the cleaning and sanitizing procedures. Also, there were no significant differences (p>0.05) in CFU.cm on the surfaces before the cleaning and sanitizing procedures, whereas different bacterial numbers were found on surfaces after the hygiene procedures. The surfaces of the milk centrifuge, raw milk cooling tank and milk packaging tank showed the largest mesophilic aerobic numbers after the hygiene, reaching 2.21, 2.18, and 1.21 log10, respectively. The results demonstrated that there is no agreement among the techniques for classification of hygienic conditions of the evaluated surfaces, showing a non-direct relation between RLU and CFU.cm. The ATP-bioluminescence method showed that 100% of the surfaces were under inadequate hygiene conditions, while the plate count method detected only 50%, based on the APHA’s recommendation, and 33%, based on the WHO’s recommendation. High variations in RLU measurements were observed, suggesting the need for more than only one surface analysis. The ATPbioluminescence is not a direct replacement for microbiological testing, but provides complementary information and should be used as part of an integrated strategy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bioluminescence ATP Monitoring for the Routine Assessment of Food Contact Surface Cleanliness in a University Canteen

ATP bioluminescence monitoring and traditional microbiological analyses (viable counting of total mesophilic aerobes, coliforms and Escherichia coli) were used to evaluate the effectiveness of Sanitation Standard Operating Procedures (SSOP) at a university canteen which uses a HACCP-based approach. To that end, 10 cleaning control points (CPs), including food contact surfaces at risk of contami...

متن کامل

Work of adhesion of dairy products on stainless steel surface

The adhesion of the solids presents in food can difficult the process of surface cleaning and promotes the bacterial adhesion process and can trigger health problems. In our study, we used UHT whole milk, chocolate based milk and infant formula to evaluate the adhesion of Enterobacter sakazakii on stainless steel coupons, and we determine the work of adhesion by measuring the contact angle as w...

متن کامل

An ASAE Meeting Presentation AN INVESTIGATION OF ATP BIOLUMINESCENCE AND QUANTITATIVE BULK TANK CULTURES TO ASSESS CLEANLINESS OF MILKING MACHINES

A series of experiments were performed to evaluate the performance of experimental detergents. Initial assessment of cleaning efficacy was done using a standardized milk soil (whole milk inoculated with bacteria) sprayed onto stainless steel test chips and allowed to incubate. These test chips were cleaned under controlled conditions in the laboratory. The residual milk soil was assessed using ...

متن کامل

Assessment of microbial growth on the surface of materials in contact with water intended for human consumption using ATP method.

Elaboration of an assessment method for plumbing materials contacting drinking water was the main purpose of this study. The investigation was conducted in 8 week cycles in dynamic conditions using a continuous flow reactor. Microbial growth was measured indirectly by a bioluminescence technique (ATP assay). Every week swabs from the surface of tested materials (polypropylene and different type...

متن کامل

Cleaning and decontamination efficacy of wiping cloths and silver dihydrogen citrate on food contact surfaces.

AIMS   To test the efficacy of four wipe cloth types (cotton bar towel, nonwoven, microfibre and blended cellulose/cotton) with either quaternary ammonia cleaning solution or silver dihydrogen citrate (SDC) in cleaning food contact surfaces. METHODS   Swab samples collected from untreated, cloth-treated and cloth disinfectant-treated surfaces were subjected to hygiene monitoring using adenosi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006