Micro-shear bond strength and surface micromorphology of a feldspathic ceramic treated with different cleaning methods after hydrofluoric acid etching
نویسندگان
چکیده
OBJECTIVE The aim of this study was to evaluate the effect of feldspathic ceramic surface cleaning on micro-shear bond strength and ceramic surface morphology. MATERIAL AND METHODS Forty discs of feldspathic ceramic were prepared and etched with 10% hydrofluoric acid for 2 minutes. The discs were randomly distributed into five groups (n=8): C: no treatment, S: water spray + air drying for 1 minute, US: immersion in ultrasonic bath for 5 minutes, F: etching with 37% phosphoric acid for 1 minute, followed by 1-minute rinse, F+US: etching with 37% phosphoric acid for 1 minute, 1-minute rinse and ultrasonic bath for 5 minutes. Composite cylinders were bonded to the discs following application of silane and hydrophobic adhesive for micro-shear bond strength testing in a universal testing machine at 0.5 mm/min crosshead speed until failure. Stereomicroscopy was used to classify failure type. Surface micromorphology of each treatment type was evaluated by scanning electron microscopy at 500 and 2,500 times magnification. RESULTS One-way ANOVA test showed no significant difference between treatments (p=0.3197) and the most common failure types were cohesive resin cohesion followed by adhesive failure. Micro-shear bond strength of the feldspathic ceramic substrate to the adhesive system was not influenced by the different surface cleaning techniques. Absence of or less residue was observed after etching with hydrofluoric acid for the groups US and F+US. CONCLUSIONS Combining ceramic cleaning techniques with hydrofluoric acid etching did not affect ceramic bond strength, whereas, when cleaning was associated with ultrasound, less residue was observed.
منابع مشابه
Effect of the Etching Duration and Ultrasonic Cleaning on Microtensile Bond Strength Between Feldspathic Ceramic and Resin Cement
This study assessed the effect of different etching time of hydrofluoric acid and ultrasonic cleaning of the etched ceramic surface on the resin microtensile bond strength stability to a feldspathic ceramic. The research hypotheses investigated were: (1) different etching time does not affect the adhesion resistance; (2) ultrasonic cleaning improves the adhesion resistance. Forty-eight (48) blo...
متن کاملComparison of traditional and simplified methods for repairing CAD/CAM feldspathic ceramics
PURPOSE To evaluate the adhesion to CAD/CAM feldspathic blocks by failure analysis and shear bond strength test (SBSt) of different restorative systems and different surface treatments, for purpose of moderate chipping repair. MATERIALS AND METHODS A self-adhering flowable composite (Vertise Flow, Kerr) containing bi-functional phosphate monomers and a conventional flowable resin composite (P...
متن کاملEffect of bonding material, etching time and silane on the bond strength of metallic orthodontic brackets to ceramic.
The purpose of this study was to evaluate the bond strength of metallic orthodontic brackets to feldspathic ceramic with different etching times, bonding materials and with or without silane application. Cylinders of feldspathic ceramic were etched with 10% hydrofluoric acid for 20 or 60 s. For each etching time, half of the cylinders received two layers of silane. Metallic brackets were bonded...
متن کاملMicromorphology of ceramic etching pattern for two CAD-CAM and one conventional feldspathic porcelain and need for post-etching cleaning.
The aim of this in vitro study was to observe the effect of hydrofluoric acid (HF) on the surface of two glass ceramics for Cerec and to compare it with the effect on a conventional glass ceramic. Discs were cut from a feldspathic ceramic block (VitaMKII) and from a leucite reinforced glass ceramic (IPS EMPRESS CAD) for Cerec. 5% and 9% HF concentrations were used during 1 min and 2 min each. A...
متن کاملComparison of Shear Bond Strength of Silorane and Methacrylate-Based Composites to IPS Empress 2 Ceramic with Various Surface Treatments
Objectives: Treatment of chipped or fractured porcelain with composite resin is considered as an economic treatment for minor fractures in ceramics. The aim of this study was to evaluate the effect of different ceramic surface treatments on bond strength of methacrylate-based and silorane-based composite resin to IPS Empress 2. Methods: Sixty IPS Empress 2 ceramic discs were fabrica...
متن کامل