Photographic measurement of the inclination of the acetabular component in total hip replacement using the posterior approach.

نویسندگان

  • J C Hill
  • D P Gibson
  • R Pagoti
  • D E Beverland
چکیده

The angle of inclination of the acetabular component in total hip replacement is a recognised contributing factor in dislocation and early wear. During non-navigated surgery, insertion of the acetabular component has traditionally been performed at an angle of 45 degrees relative to the sagittal plane as judged by the surgeon's eye, the operative inclination. Typically, the method used to assess inclination is the measurement made on the postoperative anteroposterior radiograph, the radiological inclination. The aim of this study was to measure the intra-operative angle of inclination of the acetabular component on 60 consecutive patients in the lateral decubitus position when using a posterior approach during total hip replacement. This was achieved by taking intra-operative photographs of the acetabular inserter, representing the acetabular axis, and a horizontal reference. The results were compared with the post-operative radiological inclination. The mean post-operative radiological inclination was 13 degrees greater than the photographed operative inclination, which was unexpectedly high. It appears that in the lateral decubitus position with a posterior approach, the uppermost hemipelvis adducts, thus reducing the apparent operative inclination. Surgeons using the posterior approach in lateral decubitus need to aim for a lower operative inclination than when operating with the patient supine in order to achieve an acceptable radiological inclination.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hip Arthroplasty and its Revision in a Child: Case Report and Literature Review

Juvenile idiopathic arthritis is the leading cause of hip replacement in young children. However, arthroplasty in this population is challenging with several concerns about quality of the growing bone, young age for revision surgery, and difficulties in potential several revisions. In this study we introduce a case of a 12-year old who is one of the youngest patients to undergo revision hip art...

متن کامل

Accuracy of Component Placement in Robotic-Assisted Total Hip Arthroplasty.

Robotic-assisted total hip arthroplasty (THA) is a recent platform introduced to decrease the risk of malpositioned components. The goals of this study were to determine whether intraoperative data on robotic-assisted THA acetabular component position accurately predict postoperative radiographic acetabular component position and to determine whether intraoperative data on robotic-assisted THA ...

متن کامل

To Compare Time-Weighted Graphs to Evaluate the Inclination of the Acetabular Component of Patients Who Had Total Hip Replacement Surgery

Time-weighted graphs are used to detect small shifts in statistical process control. The aim of this study is to evaluate the inclination of the acetabular component with CUmulative SUM (CUSUM) chart, Moving Average (MA) chart, and Exponentially Weighted Moving Average (EWMA) chart. The data were obtained directly from thirty patients who had undergone total hip replacement surgery at Ondokuz M...

متن کامل

Cup re-enforcement for recurrent dislocation after hip replacement.

Recurrent dislocation after total hip replacement usually demands revision. Ahnfelt (1986) reported 626 disbocations of which 79 (1 1.2%) dislocated twice, 33 (5.1%) three times and 40 dislocated (6.6%) four times. We now report the results of treating 1 3 cases of recurrent dislocation by fixing an additional sector to the posterior rim ofthe acetabular component after Charnley total hip repla...

متن کامل

[Our experience with an image guided navigation system for accurate alignment in total hip replacement by minimally invasive posterolateral surgery].

PURPOSE OF THE STUDY The aim of the study was to compare a radiographic position of the acetabular component with a position guided by the navigation system in final acetabular cup alignment. MATERIAL Between May and October 2005, 15 patients underwent implantation of a cementless acetabular component from the posterolateral minimally invasive approach with the use of kinematic navigation. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 92 9  شماره 

صفحات  -

تاریخ انتشار 2010