Evaluation of Corneal Biomechanical Properties Following Penetrating Keratoplasty Using the Ocular Response Analyzer

نویسندگان

  • Joo Young Shin
  • Jin Seok Choi
  • Joo Youn Oh
  • Mee Kum Kim
  • Jin Hak Lee
  • Won Ryang Wee
چکیده

PURPOSE To evaluate corneal biomechanical properties in eyes that had previously undergone penetrating keratoplasty (PK) using the ocular response analyzer (ORA). METHODS We recruited 26 patients who had received unilateral PK. Corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann-correlated intraocular pressure (IOPg), and cornea-compensated intraocular pressure (IOPcc) were measured with the ORA and were compared to the measurements from the contralateral eyes that did not undergo PK. RESULTS The CH was 8.95+/-2.59 mmHg in eyes that underwent PK and 9.78+/-1.45 mmHg in the contralateral eyes that did not undergo PK (p=0.077). The CRF was 10.26+/-2.64 mmHg in post-PK eyes and 9.75+/-1.45 mmHg in the contralateral eyes (p=0.509), and the CH-CRF was significantly smaller in post-PK eyes (-1.31+/-2.32 mmHg in post-PK eyes vs. 0.03+/-0.88 mmHg in fellow eyes, p=0.016). The IOPg and IOPcc were significantly higher in the PK group than they were in the control group. The IOPcc's were 20.81+/-7.81 mmHg and 16.27+/-2.49 mmHg in post-PK and control eyes, respectively (p=0.011); and the IOPg's were 19.22+/-7.34 mmHg and 15.07+/-3.03 mmHg in post-PK and control eyes, respectively (p=0.019). The IOPcc-g's were 1.59+/-2.81 mmHg and 1.21+/-1.30 mmHg in post-PK and control eyes, respectively (p=0.412), and the central corneal thickness (CCT)'s were 489.11+/-90.60 microm and 556.24+/-42.84 microm in post-PK and control eyes, respectively (p=0.068). CONCLUSIONS Following PK, CH tended to decrease while CRF tended to increase, significantly decreasing CH-CRF. A significantly higher intraocular pressure and a thinner CCT following PK may have contributed to the observed changes in these corneal biomechanical parameters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Graft Biomechanics Following Three Corneal Transplantation Techniques

PURPOSE To compare corneal biomechanical properties following three different transplantation techniques, including Descemet stripping automated endothelial keratoplasty (DSAEK), deep anterior lamellar keratoplasty (DALK) and penetrating keratoplasty (PK) in comparison to normal eyes. METHODS This cross-sectional comparative study included 118 eyes: 17 eyes of 17 patients received DSAEK, 23 e...

متن کامل

Changes in corneal biomechanics following different keratoplasty techniques

PURPOSE To evaluate corneal biomechanics with the Ocular Response Analyzer (ORA; Reichert Ophthalmic Instruments, Depew, NY) after penetrating keratoplasty (PK) and deep anterior lamellar keratoplasty (DALK). SUBJECTS AND METHODS Sixty-three eyes of 63 patients were included in this prospective comparative study. Patients were divided into 3 groups: the first included 21 eyes of normal subjec...

متن کامل

Ocular biomechanical measurements on post-keratoplasty corneas using a Scheimpflug-based noncontact device.

AIM To analyse ocular biomechanical properties, central corneal thickness (CCT) and intraocular pressure (IOP) in post-keratoplasty eyes, as compared to normal subjects, with a new Scheimpflug-based technology. Moreover, biomechanical data were correlated with the size and age of the donor and recipient corneas. METHODS Measurements were conducted on 46 eyes of 46 healthy patients without any...

متن کامل

Risk Factors for Failure of Keratoplasty in Keratoconus: Penetrating vs. Deep Anterior Lamellar Keratoplasty

Purpose: To determine the etiologic factors on rejection and failure rates and ocular surface changes after corneal transplantation by either DALK or PKP, in cases of keratoconus (KCN). Methods: In this cross-sectional study, considering the existing data, patients with keratoconus referring to Labbafinejad Medical Center from 2006 to 2016, who underwent corneal transplantation, were enrolled a...

متن کامل

Effect of Ocular Biomechanics on Intraocular Pressure Measurement in Mucopolysaccharidosis I-S (Scheie’s Syndrome)

Purpose: To study the effect of biomechanical properties of the cornea on the intraocular pressure in eyes affected with Mucopolysaccharidosis type I-S (Scheie's syndrome). Methods: Four eyes of two patients in their mid-fifties diagnosed with Scheie's syndrome were investigated for corneal biomechanical properties. The corneal biomechanical profile was assessed by the use of Ocular response an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 24  شماره 

صفحات  -

تاریخ انتشار 2010