Complete Fracture of Sirolimus-Eluting Stent in a Saphenous Vein Graft to Left Anterior Descending Artery
نویسندگان
چکیده
Coronary stent fractures have been suggested as a potential new mechanism of restenosis. The mechanical properties of stents were designed not only to prevent vessel recoil, but also to resist the mechanical stress of vessel movement over millions of cardiac cycles. We present a case in which mechanical stress may have contributed to the fracture of a stent implanted in a saphenous vein graft (SVG) to the left coronary artery. The patient was admitted due to chest pain 2 years after receiving a coronary artery bypass graft. A coronary angiography revealed the culprit vessel to be the SVG to the left coronary artery. The graft was stenosed and was stented with a sirolimus-eluting stent. A 6-month follow-up coronary angiography revealed 80% in-stent restenosis with stent fracture. We re-intervened by balloon angioplasty. This is the first report of sirolimus-eluting stent fracture combined with restenosis of SVG in Korea.
منابع مشابه
Retrograde percutaneous coronary intervention via critically degenerated saphenous vein grafts for chronic total occlusion in native coronary arteries
We report the case of a 78-year-old woman with saphenous vein graft (SVG) disease and chronic total occlusion (CTO) in three native coronary arteries [left anterior descending artery (LAD), left circumflex artery, and the right coronary artery], who was successfully treated by percutaneous coronary intervention (PCI) using the retrograde approach via the critically degenerated SVGs. The patient...
متن کاملA Case of a Zotarolimus-Eluting Stent Fracture in the Left Anterior Descending Artery in a Patient Undergoing Hemodialysis
Although stent fracture after implantation of a drug-eluting stent (DES) is a rare complication, it has been suggested to be a cause of restenosis. To date, most DES fractures have been associated with sirolimus-eluting stents. We describe here a case of a zotarolimus-eluting stent fracture after 8 months of stent placement in a calcified left anterior descending artery lesion in a patient unde...
متن کاملElectron beam computed tomographic angiography and 3-dimensional reconstruction of a stented saphenous vein graft.
A70-year-old man with exertional angina presented for cardiac catheterization. The past medical history was significant for coronary artery bypass graft surgery in 1984 with placement of a left internal mammary artery (LIMA) graft to the left anterior descending coronary artery and a single saphenous vein graft, sequentially, to 2 obtuse marginal vessels and the posterior descending coronary ar...
متن کاملMRI-induced stent dislodgment soon after left main coronary artery stenting.
S everal studies have shown the safety of MRI after coronary stenting; however, few of them included patients soon after stenting. In this report, we describe a case of MRI-induced stent dislodgment from left main coronary artery (LMCA) 2 weeks after stenting. A 56-year-old woman underwent coronary angiography for recurrence of angina 12 months after coronary artery bypass graft surgery. Corona...
متن کاملLate Thrombosis of Sirolimus-Eluting Stent: A Multifactorial Problem
We report a case of a young patient in whom a sirolimus-eluting stent was implanted on the culprit left anterior descending coronary artery at primary percutaneous coronary intervention (PCI) for acute myocardial infarction. Nine months later she suffered from a reinfarction due to the late stent thrombosis despite a continuous antiplatelet therapy with aspirin and clopidogrel. A cluster of fac...
متن کامل