Patient Dose in Digital versus Conventional Mammography

نویسندگان

  • A. 2 Floriano Miñambres
  • López Franco
چکیده

Abstract. Breast imaging techniques have received renewed attention as a proved means for earlier detection and diagnosis of breast cancer. Due to the extremely high image quality requirements in mammography, all aspects of the imaging process must be optimised. With this purpose new imaging systems have been incorporated. The aim of this paper is to present results of patient dose comparison in different digital and conventional imaging systems. The sample size was 240 patients (2 mammogram per patient) and 8 mammography units participated in the study: 3 G.E. Senographe. DMR, 2 G.E. Senographe 600T(with film-screen system Fuji UMMA HC/Agfa Detail R, HDR/Agfa Detail R, Agfa Mamoray HT/Agfa Detail R), 1 G. E. Senographe 500 T and 1 General Merate MSM with computed radiology system (Fuji FCR 5000 MA plus and Fuji IP / DI-HL photostimulable phosphor), and 1 G.E. Senographe 2000 d with flat-panel system. Radiographic technique (kVp, mAs, focus-image receptor distance, filter /anode combination and compress breast thickness) were recorded for each projection. By using the post exposure mAs (when was possible) and the output measured in the quality control programme, the entrance surface dose (ESD) was calculated. All results obtained (except in equipment num.7,MLO projection) were lower than ESD reference values, but mean values in digital modalities were higher than in conventional ones. However other aspects that contribute to the global patient dose, as the reject rate, were significantly lower in digital systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Breast dose in conventional and digital mamography

Introduction: The amount of doses received in mammography is one of the biggest concerns in the world. According to some statistics, every 12 minutes a woman dies due to breast cancer. Mammography concerned to detect breast cancer at an early stage of the disease as well as for screening, however due to the risk of exposure, the increasingly and widespread use of mammography fo...

متن کامل

مقایسه میزان دز جذبی پستان در دستگاه ماموگرافی معمولی و دیجیتال در شرایط مورد استفاده دستگاه‌ها در تبریز

Background: The amount of doses received in mammography is one of the biggest concerns in the world. According to some statistics, every 12 minutes a woman dies due to breast cancer. Mammography concerned to detect breast cancer at an early stage of the disease as well as for screening, however due to the risk of exposure, the increasingly and widespread use of mammography for breast cancer scr...

متن کامل

Estimation of Mean Estimation of Mean Glandular Dose in Mammography Examination in some of Radiology Centers in Tehran city

Introduction: the objectives of this research were determination of Mean Glandular Dose in film- screen and digital mammography examinations, estimation of accumulated effective dose in some of mammography centers in Tehran city and estimating cancer risk due to these examinations. Materials and Methods: the clinical data were collected from the 1318 <...

متن کامل

Comparison Between Film-Screen and Digital Mammography for Woman Breast Cancer Screening: Mean Glandular Dose

Introduction: Most studies in mammography have only been carried out in a comparison of image quality and lesion detection in film-screen mammography (FSM) and full field digital mammography (FFDM) systems. The aim of this paper was to evaluate mean glandular dose (MGD) of patient and affecting factors by FSM and FFDM to estimate which one gives a brief radiation protection to patient. Material...

متن کامل

Patient effective dose evaluation for chest X-ray examination in three digital radiography centers

Background: The radiation doses resulting from diagnostic X-ray examinations are routinely measured in terms of entrance surface dose (ESD) and effective dose (ED). In this study, for the purpose of radiation protection, the radiation doses received from Digital chest X-ray examination were evaluated in terms of ESD and ED. Material and Methods: The ED was calculated by using the MCNP ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004