Imaging Spectrum and Pitfalls of 11C-Methionine Positron Emission Tomography in a Series of Patients with Intracranial Lesions
نویسندگان
چکیده
(11)C-methionine (Met) positron emission tomography (PET) is one of the most commonly used PET tracers for evaluating brain tumors. However, few reports have described tips and pitfalls of (11)C-Met PET for general practitioners. Physiological (11)C-Met uptake, anatomical variations, vascular disorders, non-tumorous lesions such as inflammation or dysplasia, benign brain tumors and patient condition during (11)C-Met PET examination can potentially affect the image interpretation and cause false positives and negatives. These pitfalls in the interpretation of (11)C-Met PET images are important for not only nuclear medicine physicians but also general radiologists. Familiarity with the spectrum and pitfalls of (11)C-Met images could help prevent unfavorable clinical results caused by misdiagnoses.
منابع مشابه
Diagnosis of Brain Tumors Using Amino Acid Transport PET Imaging With 18F- Fluciclovine: A Comparison Study With L-Methyl-11C-Methionine PET Imaging
Objective(s): 18F-fluciclovine (trans-1-amino-3-[18F] fluorocyclobutanecarboxylic acid, [FACBC]) is an artificial amino acid radiotracer used for positron emission tomography (PET) studies, which is metabolically stable in vivo and has a long half-life. It has already been shown that FACBC-PET is useful for glioma imaging. However, there have been no reports evaluating the efficiency of FACBC-P...
متن کاملCalculation of Positron Distribution in the Presence of a Uniform Magnetic Field for the Improvement of Positron Emission Tomography (PET) Imaging Using GEANT4 Toolkit
Introduction Range and diffusion of positron-emitting radiopharmaceuticals are important parameters for image resolution in positron emission tomography (PET). In this study, GEANT4 toolkit was applied to study positron diffusion in soft tissues with and without a magnetic field for six commonly used isotopes in PET imaging including 11C, 13N, 15O, 18F, 68Ga, and 82Rb. Materials and Methods GEA...
متن کاملUsefulness of 11C-methionine positron emission tomography for detecting intracranial ameloblastic carcinoma: A case report
Ameloblastic carcinoma, secondary type, is an extremely rare odontogenic malignant tumor. The present study reports the case of a 58-year-old male with ameloblastic carcinoma that extended into the intracranial space close to the internal carotid artery. Surgical excision was performed, as headaches were being caused via compression by the mass. Small remnants of the tumor remained surrounding ...
متن کاملImportance of defect detectability in Positron Emission Tomography imaging of abdominal lesions
Objective(s): This study was designed to assess defect detectability in positron emission tomography (PET) imaging of abdominal lesions. Methods: A National Electrical Manufactures Association International Electrotechnical Commission phantom was used. The simulated abdominal lesion was scanned for 10 min using dynamic list-mode acquisition method. Images, acquired with scan duration of 1-10 mi...
متن کاملC-11 Choline and FDG PET/CT Imaging of Primary Cholangiocarcinoma – a Comparative Analysis
Objective(s): This study aimed to compare the diagnostic values of 11C-choline and 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) in patients with cholangiocarcinoma (CCA). Methods: This prospective study was conducted on 10 patients (6 males and 4 females), aged 42-69 years, suspected of having CCA based on CT or magnetic resonance imaging (MRI) resu...
متن کامل