Radiation safety issues with high activities of liquid I‐125: Techniques and experience
نویسندگان
چکیده
The handling of a liquid radioactive source is a procedure that is uncommon for the average clinical medical physicist. A newly approved treatment device utilizes high activities of liquid I-125 solution as the source of radiation. The radiation safety issues and our experience utilizing high activity liquid I-125 sources are presented. To date we have treated 22 patients with infused activities ranging up to 26.8 GBq (724 mCi). The careful manipulation of such solutions is important to maintain a safe environment for the patients and the involved medical staff.
منابع مشابه
Estimation of dosimetric parameters of I-125 brachytherapy source model 6711 using GATE8.1 code
Brachytherapy is one type of internal radiation therapy where radiation sources, which are usually encapsulated are placed as close as possible to the tumor site inside the patient's body. In this technique, it is important to determine dose distribution around the brachytherapy capsule. Hereby, in this paper, dosimetric parameters of I-125 brachytherapy source model 6711 are estimated accordin...
متن کاملHigh dose radioiodine outpatient treatment: an initial experience in Thailand
Objective(s): The aim of this study was to determine whether high-dose radioactive iodine (Na131I) outpatient treatment of patients with thyroid carcinoma is a pragmatically safe approach, particularly for the safety of caregivers. Methods: A total of 79 patients completed the radiation-safety questionnaires prior to receiving high-dose radioactive iodine treatment. The questionnaire studied th...
متن کاملPersonnel internal radiation exposure to iodine-125 in a radioiodination laboratory: Exposure levels and trends
ABSTRACT Background: Monitoring internal exposure of individuals handling significant amounts of iodine-125 (I-125) for iodination is of great importance. These individuals are potentially exposed to external contamination, and internal contamination through inhalation, ingestion and intact skin absorption, to I-125. Considering radiological toxicity of this radionuclide its monitoring in the w...
متن کاملRadiation Safety Analysis, 2 Models of Industrial Radiography Techniques in Tubes Testing Using SuperMc 3.2
In this article, we used SuperMc 3.2 Software for have studied two models of welding radiographic techniques that are more common in radiographs (Dobell Walls and Single Image (DWSI) and Single Wall and Single Image (SWSI) technique) , without the use of a collimator and in terms of radiation risk and radiation safety. According to results, Due to the lack of a collimator, the risk of radiation...
متن کاملRadiation safety issues regarding the cremation of the body of an I‐125 prostate implant patient
Radiation exposure to the public is estimated if the body of an I-125 prostate implant patient is cremated. Precautions regarding the handling of cremated remains are suggested. Cremation can be performed safely at any time.