Utilization of C-MAC videolaryngoscopy for direct and indirect assisted endotracheal intubation

نویسندگان

  • Davide Cattano
  • Lara Ferrario
  • Chirag B. Patel
  • Vineela Maddukuri
  • Vladimir Melnikov
  • Sam D. Gumbert
  • Alfonso V. Altamirano
  • Carin A. Hagberg
چکیده

Background: The experiences of seasoned practitioners with the new C-MAC indirect videolaryngoscope system have shown promising results in the management of difficult airways. However, a comparison of direct and indirect laryngoscopy utilizing the C-MAC system as its own control has not been performed in a cohort of anesthesiologists-in-training. The primary aim was to compare direct and indirect laryngoscopy in terms of intubation time with secondary outcomes including laryngoscopy time and airway view with the same size 3 blade. Methods: The study was registered with www.clinicaltrials.gov (NCT01104090). Oral and written informed consent was obtained from 50 adult patients with BMI < 40 kg/m2 who required general anesthesia for elective surgery with tracheal tube placement. The patients were randomized to two groups, each receiving two laryngoscopies, n=25 direct-first and n=25 indirect-first. Results: All patients except for one were successfully intubated on the first attempt. The intubation time was 12.3±11.1 sec immediately following videolaryngoscopy (direct laryngoscopy first group) and 9.8±7.1 sec immediately following direct laryngoscopy (videolaryngoscopy first group), p=0.35. The first laryngoscopy time was 8.7±4.7 sec in the direct group and 13.3±10.7 sec in the indirect group, p=0.06. Twenty-percent of direct first cases compared to 0% of indirect first cases showed an improvement in airway view score by at least two classes on the second laryngoscopy, p=0.02. Backward-upward-rightward pressure was used in 36% of direct first and 12% of indirect first patients, p=0.047. Conclusions: This study corroborates previous results on the use of the C-MAC videolaryngoscopy system during endotracheal-assisted intubation. Although there was no difference in intubation time between direct laryngoscopy and videolaryngoscopy, the C-MAC system was found to improve laryngeal views and reduce the number of necessary laryngeal manipulations. A larger randomized study utilizing a similar model is necessary to definitively determine significant clinical results. Trial registration: ClinicalTrials.gov NCT01104090.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hands-Off Time for Endotracheal Intubation during CPR Is Not Altered by the Use of the C-MAC Video-Laryngoscope Compared to Conventional Direct Laryngoscopy. A Randomized Crossover Manikin Study

INTRODUCTION Sufficient ventilation and oxygenation through proper airway management is essential in patients undergoing cardio-pulmonary resuscitation (CPR). Although widely discussed, securing the airway using an endotracheal tube is considered the standard of care. Endotracheal intubation may be challenging and causes prolonged interruption of chest compressions. Videolaryngoscopes have been...

متن کامل

A randomised, controlled crossover comparison of the C-MAC videolaryngoscope with direct laryngoscopy in 150 patients during routine induction of anaesthesia

BACKGROUND The C-MAC® (Karl Storz, Tuttlingen, Germany) has recently been introduced as a new device for videolaryngoscopy guided intubation. The purpose of the present study was to compare for the first time the C-MAC with conventional direct laryngoscopy in 150 patients during routine induction of anaesthesia. METHODS After approval of the institutional review board and written informed con...

متن کامل

Hemodynamic responses to endotracheal intubation performed with video and direct laryngoscopy in patients scheduled for major cardiac surgery.

This study aims to compare the hemodynamic responses to endotracheal intubation performed with direct and video laryngoscope in patients scheduled for cardiac surgery and to assess the airway and laryngoscopic characteristics. One hundred ten patients were equally allocated to either direct Macintosh laryngoscope (n = 55) or indirect Macintosh C-MAC video laryngoscope (n = 55). Systolic, diasto...

متن کامل

Implementing videolaryngoscopy in anaesthetist-staffed pre-hospital critical care

Background Pre-hospital endotracheal intubation may be challenging, even in expert hands [1,2]. Difficult or failed endotracheal intubations are associated with complications that can be life threatening [1] and the risk of complications increases when the first endotracheal intubation attempt is not successful [2]. The McGRATH MAC videolaryngoscope may have the potential to improve first-pass ...

متن کامل

McGRATH MAC videolaryngoscope versus Macintosh laryngoscope for orotracheal intubation in intensive care patients: the randomised multicentre MACMAN trial study protocol

INTRODUCTION Critically ill patients with acute respiratory, neurological or cardiovascular failure requiring invasive mechanical ventilation are at high risk of difficult intubation and have organ dysfunctions associated with complications of intubation and anaesthesia such as hypotension and hypoxaemia. The complication rate increases with the number of intubation attempts. Videolaryngoscopy ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013