Evaluation of the Dimension XL clinical chemistry system
نویسندگان
چکیده
The analytical performance of the Dimension XL clinical chemical system was evaluated. The XL is the latest addition to the Dimension family of instruments; it is a random access analyser with a throughput up to 740 tests/hour. Regression analysis of method comparison studies with Dimension AR yielded slopes of 0.93 to 1.03 and correlation coefficients >/=0.96 for 28 assays. Excellent precision performance was also observed. New instrument features of the XL are discussed.
منابع مشابه
Development and analytical performance of an automated screening method for cannabinoids on the Dimension clinical chemistry system
A fully automated, random access method for the determination of cannabinoids (UTHC) was developed for the Dimension AR and XL clinical chemistry systems. The method utilizes Abuscreen ONLINE reagents and a multianalyte liquid calibrator containing 11-nor-Delta(9)-THC-9-carboxylic acid. Within-run and total reproducibility, determined using NCCLS protocol EP5- T2, was less than 0.6% and 1.6% CV...
متن کاملSodium Alginate/Starch Blends Loaded with Ciprofloxacin Hydrochloride as a Floating Drug Delivery System - In Vitro Evaluation
In the present study, Floating Drug Delivery Beads (FDDS) were prepared with sodium alginate/ starch blend as a matrix, sodium hydrogen carbonate as a pore forming agent, methyl cellulose as a binder and barium chloride solution as a hardening agent. In order to prepare the beads with different porosity and morphology the ratio between pore forming agent to polymer blend and ratio of the co...
متن کاملآسیبشناسی نظام یادگیری الکترونیکی دانشگاههای علوم پزشکی بر اساس مدل خان
Introduction: Information and communication technology has led to emergence of new ways of teaching and learning. E-learning is one of the new ways of learning in the present era. For the e-learning system to be effective, the current e-learning system should be assessed and. The aim of the present study was to investigate the pathology of e-Learning system in Tehran University of Medical Scien...
متن کاملSolid Sirolimus Self-microemulsifying Drug Delivery System: Development and Evaluation of Tablets with Sustained Release Property
The clinical application of sirolimus (SRL) as an immunosuppressive agent is largely hampered by its narrow therapeutic range. This study focused on developing SRL tablets with a sustained release profile for better safety. SRL was highly water insoluble and its solubility has been efficiently enhanced by preparing self-microemulsifying drug delivery system (SMEDDS). The SRL-SMEDDS was physical...
متن کاملLaboratory evaluation of the Du Pont "Dimension Clinical Chemistry System".
We evaluated the analytical performance of the Du Pont Dimension Clinical Chemistry System to assess its suitability as a replacement for the Du Pont aca III, currently routinely used for analysis of pediatric, high-risk, and emergency specimens. Twenty-six analyses were studied. These generally fulfilled pre-set analytical goals for precision based on biological variation or "state of the art....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of Automatic Chemistry
دوره 19 شماره
صفحات -
تاریخ انتشار 1997