A Simple and Inexpensive Evaporator Entrainment Separator
نویسندگان
چکیده
Use of angle iron separators in two evaporator vessels at Darnall resulted in a marked reduction in entrainment rates. Efficiencies in excess of 90% were observed with negligible pressure differential across the separator. Separator efficiency can be evaluated rapidly by using a centrally based Auto-Analyser. Introduction To avoid sugar losses by entrainment, all evaporator vessels are fitted with some means of separating droplets of juice from the vapour stream. Numerous designs of "save-alls" or "entrainment separators" are currently in use, the principle of operation being that from a change in direction and velocity of the vapour, small droplets of juice are collected and returned to the juice surface. Evaporator Station The layout of the evaporator station at Darnall is described in Figure 1 showing the steam flow only. It should be noted that while Fletcher 2 supplies vapour to Fletcher 3 and 4 in parallel, the juice remains series connected.
منابع مشابه
Test Results of A Screw Type Expander/Compressor and the Implication of Phase Separators on the Refrigeration Process
Running a refrigeration cycle at saturated liquid conditions at the evaporator inlet has a few interesting advantages in comparison to the conventional 2-phase situation. Opportunities in using novelty heat exchangers, increased cycle efficiency and significantly reduced main compressor sizes occur. Using the two rotor integrated compressor/expander idea developed by Olofsson (1993) in a refrig...
متن کاملExperimental Study on the Performance of Dual-Evaporator Refrigeration System with an Ejector
Experimental investigation on the performance of dual-evaporator refrigeration system with an ejector has been carried out In this study, HFC-134a is chosen as a working fluid. Test setup is composed of compressor, condenser, expansion valves, two evaporators, and ejector which is installed between two evaporators. The condenser and two evaporators are made as concentric counter-flow type heat ...
متن کاملPerformance and Reliability Degradation of a Residential Unitary Air Conditioning System Resulting from a Mismatch of a 1992 Air Conditioning Unit with a 15-20 Year Old Evaporator
Fred Keller Split Systems Director The National Appliance Energy Conservation Act has established a minimum efficiency of 10 SEER for residential split system air conditioners and heat pumps. Approximately 50% of residential split system air conditioners are sold as replacements for units having much lower SEER levels, typically 5-9 Btu/W·h. This investigation assessed the detrimental affects t...
متن کاملImplementation of Microchannel Evaporator for High - Heat - Flux Refrigeration Cooling Applications
While most recently electronic cooling studies have been focused on removing the heat from high-power-density devices, the present study also explores means of greatly decreasing the device operating temperature. This is achieved by incorporating a microchannel heat sink as an evaporator in an R134a refrigeration loop. This system is capable of maintaining device temperatures below 55°C while d...
متن کاملExperimental Comparison of the Performance of Refrigerants R134a and R32/R134a in Dry Expansion and Liquid Recirculation Refrigerating Systems
The ability of zeotropic mixtures with a temperature glide to operate in liquid recirculation systems is investigated in this paper, and the preliminary results of an experimental comparison between the performance of R134a and of zeotropic mixture R32/Rl34a, (25/75 by mass) are presented. The perfonnance of Rl34a operating in dry expansion mode are also presented as baseline data. INTRODUCTION...
متن کامل