Factors Predicting Ventilator Dependence in Patients with Ventilator-Associated Pneumonia
نویسندگان
چکیده
OBJECTIVES To determine risk factors associated with ventilator dependence in patients with ventilator-associated pneumonia (VAP). STUDY DESIGN A retrospective study was conducted at Chang Gung Memorial Hospital, Kaohsiung, from January 1, 2007 to January 31, 2008. METHODS This study evaluated 163 adult patients (aged ≥ 18 years). Eligibility was evaluated according to the criterion for VAP, Sequential Organ Failure Assessment (SOFA) score, Acute Physiological Assessment and Chronic Health Evaluation II (APACHE II) score. Oxygenation index, underlying comorbidities, septic shock status, previous tracheostomy status, and factors related to pneumonia were collected for analysis. RESULTS Of the 163 VAP patients in the study, 90 patients survived, yielding a mortality rate of 44.8%. Among the 90 surviving patients, only 36 (40%) had been weaned off ventilators at the time of discharge. Multivariate logistic regression analysis was used to identify underlying factors such as congestive cardiac failure (P = 0.009), initial high oxygenation index value (P = 0.04), increased SOFA scores (P = 0.01), and increased APACHE II scores (P = 0.02) as independent predictors of ventilator dependence. Results from the Kaplan-Meier method indicate that initial therapy with antibiotics could increase the ventilator weaning rate (log Rank test, P < 0.001). CONCLUSIONS Preexisting cardiopulmonary function, high APACHE II and SOFA scores, and high oxygenation index were the strongest predictors of ventilator dependence. Initial empiric antibiotic treatment can improve ventilator weaning rates at the time of discharge.
منابع مشابه
بروز پنومونی مرتبط با تهویه مکانیکی و عوامل خطر مرتبط با آن در بخشهای مراقبت ویژه
Background: Ventilator-Associated Pneumonia is the most important cause of mortality of nosocomial infections. Still incidence of ventilator-associated pneumonia and its related risk factors in routine nursing care in the intensive care unit has not been studied. The aim of this study was to determine the incidence of Ventilator-Associated in intensive care units and its relationship with risk ...
متن کاملVentilator – associated pneumonia in intensive care units And physician - nurse relationship role
Introduction: Ventilator-associated pneumonia is one of important factors of morbidity and mortality in critical care units, associated with hospitalization day’s and increased cost of treatment. Thus prevention through identifying related factors must be highly recommended Objective: This study is conducted by the aim of determining the nurses understanding of physician-nurse relation...
متن کاملDoes Re-intubation Increased Risk of Ventilator- Associated Pneumonia (VAP) in Pediatric Intensive Care Unit Patients?
Introduction:ventilator- associated pneumonia(VAP),as defined by the centers for disease control and prevention (CDC),is a pneumonia that occurs in a patient receiving mechanical ventilation that develops 48 hours or more after initiation of ventilation.re-intubation which occur within 72 hours of planned extubation may effect VAP incidence.the aim of this study was to determine VAP incidence i...
متن کاملThe prevalence of Mycoplasma pneumoniae infection in patients with ventilator-associated pneumonia hospitalized in intensive care unit
Background: Ventilator-associated pneumonia (VAP) is a type of hospital acquired pneumonia with the mortality rate between 27% and 76% that develops more than 48–72 h after endotracheal intubation. Possible causes leading to this infection can be Mycoplasma pneumoniae. The objective of this study was to determine the presence of Mycoplasma pneumoniae in bronchoalveolar samples of patients with ...
متن کاملComparing the Effect of Using Normal Saline and Distilled Water for Tracheal Suctioning on the Incidence of Ventilator-associated Pneumonia and Hemodynamic Indexes in Ventilator-dependent Patients
Background and Aims: VAP prevention is a top priority in the intensive care units. The study was conducted to compare the effect of using normal saline and distilled water for tracheal suctioning on the incidence of ventilator-associated pneumonia and hemodynamic indexes in ventilator-dependent patients. Methods: The present study is a randomized clinical trial that was conducted from 2017 to 2...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2012 شماره
صفحات -
تاریخ انتشار 2012