Catastrophic osteomyelitis following percutaneous wire fixation of a distal radial fracture: a cautionary tale of poor patient selection followed by surgical mishap.
نویسندگان
چکیده
We present a case of distal radius fracture. Several sequential unfortunate events resulted in a poor outcome. The patient was poorly selected because the degree of early dementia was not fully appreciated, due to intermittent periods of lucidity. Having elected to treat this distal radius fracture with Kirschner wires, a wire snapped during the procedure and was deemed safe to leave within the medullary cavity. Subsequently, the patient was left in a cast for 4 weeks without regular pin site inspection. When the cast was removed a gross osteomyelitis had developed. This series of events, led to unnecessary morbidity and extended the immobilisation time with reduced wrist function. This case highlights the importance of careful patient selection, surgical tactics and continuity of care.
منابع مشابه
Discharging pin sites following K-wire fixation of distal radial fractures: a case for pin removal?
The aim of this study was to find out whether discharging pin sites following Kirschner-wire fixation of distal radial fractures warrant early wire removal. In a prospective study of 50 patients with a closed distal radial fracture treated by manipulation and either percutaneous or mini-incision Kirschner-wiring, we identified 14 patients (28%) with discharging pin sites. All of the cases were ...
متن کاملAcute Combined Median and Radial Nerve Palsies after Distal Humeral Shaft Fracture
We report a case of a 29-year-old man who presented with a distal humeral shaft fracture sustained by blunt trauma. Physicalexamination and nerve conduction study were consistent with injury to the median and radial nerves proximal to theelbow. The patient underwent open reduction and internal fixation of the humeral shaft fracture with neurolysis of the medianand radial nerves. Repeat electrom...
متن کاملAcomparison of percutaneous and pin-and-plaster techniques in distal radius fracture
Abstract Background: Distal Radial fracture is one of the most common fractures of the skeletal system. Although it has been believed to be a simple fracture with excellent outcomes, practical operations’ results have always been undesirable and even poor. The goal of this study was to compare two methods of treatment “pin and plaster and precautious pin fixation in patients with unstable extr...
متن کاملComparison of close reduction and percutaneous pin fixation as treatments for distal metaphyseal radius fractures
Background: Distal radius fractures are one of the most common fractures of skeletal system and because of the aging of population, its incidence is rising. The aim of the present research was to evaluate the close reduction and percutaneous pin fixation as a treatment option. Material and methods: 44 patients who were type 2 according to universal classification or type 2 or 3 according to Ol...
متن کاملمقایسه نتایج جااندازی بسته با پینگذاری از راه پوست و جااندازی باز با فیکساسیون داخلی در شکستگی سوپراکندیلار بازو در بچهها
ABSTRACT Type III supracondylar fractures of humerus is a common fracture of children with high rate of complications. There is many contraversies about its treatment. Closed reduction and percutaneous pin fixation and also open reduction and internal fixation are two routine surgical methods for this fracture each with own risk and benefits. This is a retrospective study on 49 patient...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- BMJ case reports
دوره 2013 شماره
صفحات -
تاریخ انتشار 2013