Experiences with the European guidelines on quality criteria for radiographic images in Tanzania

نویسندگان

  • W. E. Muhogora
  • A. M. Nyanda
  • R. R. Kazema
چکیده

Objective assessment of the quality of radiographic images is practically a difficult task and protocols that address this problem are few. In 1996, the European union published nearly objective image quality criteria to unify the practices in Europe. However, experience with these criteria in countries of lower health care levels is little documented. As a case study in Tanzania, we present the general performance of European guidelines in some Tanzanian hospitals to a total of 200 radiographs obtained from some common x-ray examinations. The results show that more than 70% of chest (PA), lumbar spine (AP), and pelvis AP radiographs passed the quality criteria, while the performance of lumbar spine LAT x-ray examinations was about 50% and therefore less satisfactory. The corresponding mean entrance dose to the patient for specified x-ray techniques was of range 0.08-0.56 mGy, 3.1-7.7 mGy, 2.53-5.4 mGy, and 4.0-16.78 mGy for chest PA, lumbar spine AP, pelvis AP, and lumbar spine LAT x-ray examinations, respectively. Although a good number of observers were not well familiar to the guidelines, the quality criteria have been found useful and their adoption in the country recommended. The need to provide relevant education and training to staff in the radiology departments is of utmost importance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی میزان کیفیت تصاویر رادیوگرافی در بیمارستان های ارجاعی دولتی شهرستان ساری در سال 96

Background and purpose: Image quality together with low patient dose is two important goals in radiography procedures. Acquire radiographic images with inadequate quality give rise to uselessly patient dose, improper diagnosis, waste the cost and impose the biological effect to the patients. In this study image quality was evaluated for most common radiographic procedures based on indentified i...

متن کامل

بررسی میزان انطباق بخش های رادیوگرافی در بیمارستان های دولتی استان مازندران با راهنمای استاندارد CEC و عوامل مرتبط با آن در سال 1390

Abstract Background and purpose: The Commission of European Communities (CEC) has developed a guideline in which many common radiographic techniques are determined. Following these guidelines will reduce patient dose and good quality image is obtained. Noncompliance of radiographic centers with standard guidelines not only leads to reduction in radiographic image quality but also wastes reso...

متن کامل

What Can We Learn About the Processes of Regulation of Tuberculosis Medicines From the Experiences of Health Policy and System Actors in India, Tanzania, and Zambia?

Background The unregulated availability and irrational use of tuberculosis (TB) medicines is a major issue of public health concern globally. Governments of many low- and middle-income countries (LMICs) have committed to regulating the quality and availability of TB medicines, but with variable success. Regulation of TB medicines remains an intractable challenge in many settings, but the reason...

متن کامل

Optimization of Dose and Image Quality in Full-fiand Computed Radiography Systems for Common Digital Radiographic Examinations

IntroductionA fine balance of image quality and radiation dose can be achieved by optimization to minimize stochastic and deterministic effects. This study aimed in ensuring that images of acceptable quality for common radiographic examinations in digital imaging were produced without causing harmful effects. Materials and MethodsThe study was conducted in three phases. The pre-optimization inv...

متن کامل

Evaluation of the Influence of Exposure Index on Image Quality and Radiation Dose

Introduction: The introduction of digital radiography has led to a significant problem in terms of dose creep. To address this problem, manufacturers have established a set of exposure indicators (EI) as a feedback mechanism to safeguard against overexposure. The EI is the measure of incident exposure to the detector that is directly proportional to the signal-to-noise...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2001