Misplacement of left-sided double-lumen tubes into the right mainstem bronchus: incidence, risk factors and blind repositioning techniques

نویسندگان

  • Jeong-Hwa Seo
  • Jun-Yeol Bae
  • Hyun Joo Kim
  • Deok Man Hong
  • Yunseok Jeon
  • Jae-Hyon Bahk
چکیده

BACKGROUND Double-lumen endobronchial tubes (DLTs) are commonly advanced into the mainstem bronchus either blindly or by fiberoptic bronchoscopic guidance. However, blind advancement may result in misplacement of left-sided DLTs into the right bronchus. Therefore, incidence, risk factors, and blind repositioning techniques for right bronchial misplacement of left-sided DLTs were investigated. METHODS This was an observational cohort study performed on the data depository consecutively collected from patients who underwent intubation of left-sided DLTs for 2 years. Patients' clinical and anatomical characteristics were analyzed to investigate risk factors for DLT misplacements with logistic regression analysis. Moreover, when DLTs were misplaced into the right bronchus, the bronchial tube was withdrawn into the trachea and blindly readvanced without rotation, or with 90° or 180° counterclockwise rotation while the patient's head was turned right. RESULTS DLTs were inadvertently advanced into the right bronchus in 48 of 1135 (4.2 %) patients. DLT misplacements occurred more frequently in females, in patients of short stature or with narrow trachea and bronchi, and when small-sized DLTs were used. All of these factors were significantly inter-correlated each other (P < 0.001). In 40 of the 48 (83.3 %) patients, blind repositioning was successful. CONCLUSIONS Smaller left-sided DLTs were more frequently misplaced into the right mainstem bronchus than larger DLTs. Moreover, we were usually able to reposition the misplaced DLTs into the left bronchus by using the blind techniques. TRIAL REGISTRATION ClinicalTrials.gov Identifier: NCT01371773.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrical impedance tomography to confirm correct placement of double-lumen tube: a feasibility study.

BACKGROUND Double-lumen tubes (DLTs) are frequently used to establish one-lung ventilation (OLV). Their correct placement is crucial. We hypothesized that electrical impedance tomography (EIT) reliably displays distribution of ventilation between left and right lung and may thus be used to verify correct DLT placement online. METHODS Regional ventilation was studied by EIT in 40 patients requ...

متن کامل

Left mainstem bronchial rupture during one-lung ventilation with Robertshaw double lumen endobronchial tube -A case report-

Lung separation using a double-lumen endobronchial tube is necessary for video assisted thoracoscopy (VATs). Bronchial rupture after intubation with a double-lumen endobronchial tube has been rarely reported. We report a case of a 70-year-old man who had solitary pulmonary nodule in his right upper lobe. He was intubated with a left-sided Robertshaw double-lumen endobronchial tube. He underwent...

متن کامل

Left mainstem bronchus rupture due to a left-sided double lumen tube.

Double lumen tubes (DLT) are a cornerstone in thoracic anaesthesia to achieve onelung ventilation. Due to the shape and size of these devices, airway injuries might occur. The reported incidence of tracheobronchial ruptures caused by a DLT is very low (0.005% for single-lumen tubes and 0.05% for double-lumen intubations), but the outcome can be life-threatening (1, 2). In the past, treatment of...

متن کامل

The height-based formula for prediction of left-sided double-lumen tracheal tube depth.

In the commonly used double-lumen tube (DLT) intubation procedure, the tip of a DLT is inserted into the mainstem bronchus in a blind fashion, followed by determination of precise DLT position by a fiberoptic bronchoscope. Several studies have suggested that insertion depth for a left-sided DLT is correlated with physical factors including height and neck length.1-3 However, there are no widely...

متن کامل

"Detachment of the carinal hook following endobronchial intubation with a double lumen tube"

BACKGROUND Carinal hooks increases difficulty at endotracheal intubation. Amputation of the carinal hook during passage and malpositioning of the tube to the hook are some of the potential problems related with left-sided Carlens double lumen tube (DLT). This article reports an amputation of the hook during a difficult selective intubation and aimed at calling the attention to complications ass...