forearm/wrist rehabilitation functionality to the UCI BONES exoskeleton robot and to the ArmeoSpring rehabilitation device. SUE is a 2-DOF serial chain that can measure and assist forearm supination-pronation and wrist
نویسندگان
چکیده
The robot described in this paper, SUE (Supinator Extender), adds forearm/wrist rehabilitation functionality to the UCI BONES exoskeleton robot and to the ArmeoSpring rehabilitation device. SUE is a 2-DOF serial chain that can measure and assist forearm supination-pronation and wrist flexion-extension. The large power to weight ratio of pneumatic actuators allows SUE to achieve the forces needed for rehabilitation therapy while remaining lightweight enough to be carried by BONES and ArmeoSpring. Each degree of freedom has a range of 90 degrees, and a nominal torque of 2 ft-lbs. The cylinders are mounted away from the patient’s body on the lateral aspect of the arm. This is to prevent the danger of a collision and maximize the workspace of the arm robot. The rotation axis used for supination-pronation is a small bearing just below the subject’s wrist. The flexion-extension motion is actuated by a cantilevered pneumatic cylinder, which allows the palm of the hand to remain open. Data are presented that demonstrate the ability of SUE to measure and cancel forearm/wrist passive tone, thereby extending the active range of motion for people with stroke.
منابع مشابه
Functional Outcome of Internal Fixation of Radial and Ulna Fracture
Background: Displaced fractures of radius and ulna bones in adults are usually treated with open reduction and internal fixation. The purpose of this research was to access functional outcome of these fractures. Materials and Methods: In this research 52 Patients who underwent ORIF with DCP 3.5 in past 5 years were investigated. Post-operation protocol was one week immobilization and then acti...
متن کاملThe passive stiffness of the wrist and forearm.
Because wrist rotation dynamics are dominated by stiffness (Charles SK, Hogan N. J Biomech 44: 614-621, 2011), understanding how humans plan and execute coordinated wrist rotations requires knowledge of the stiffness characteristics of the wrist joint. In the past, the passive stiffness of the wrist joint has been measured in 1 degree of freedom (DOF). Although these 1-DOF measurements inform u...
متن کاملTwo-degree-of-freedom powered prosthetic wrist.
Prosthetic wrists need to be compact. By minimizing space requirements, a wrist unit can be made for people with long residual limbs. This prosthetic wrist uses two motors arranged across the arm within the envelope of the hand. The drive is transmitted by a differential so that it produces wrist flexion and extension, pronation and supination, or a combination of both. As a case study, it was ...
متن کاملA Real-time Motion Tracking Wireless System for Upper Limb Exosuit Based on Inertial Measurement Units and Flex Sensors (TECHNICAL NOTE)
This paper puts forward a real-time angular tracking (motion capture) system for a low cost upper limb exosuit based on sensor fusion; which is integrated by an elastic sleeve-mitten, two inertial measurement units (IMU), two flex sensors and a wireless communication system. The device can accurately detect the angular position of the shoulder (flexion-extension, abduction-adduction and interna...
متن کاملHyperstaticity for Ergonomic Design of a Wrist Exoskeleton
Increasing the level of transparency in rehabilitation devices has been one of the main goals in robot-aided neurorehabilitation for the past two decades. This issue is particularly important to robotic structures that mimic the human counterpart’s morphology and attach directly to the limb. Problems arise for complex joints such as the human wrist, which cannot be accurately matched with a tra...
متن کامل