Evaluation of an auto-CPAP device for treatment of obstructive sleep apnoea.

نویسندگان

  • J H Ficker
  • G H Wiest
  • G Lehnert
  • B Wiest
  • E G Hahn
چکیده

BACKGROUND Auto-CPAP machines used in the treatment of obstructive sleep apnoea (OSA) are designed to vary the treatment pressure automatically in order always to apply the actually needed pressure. Consequently they should be able to achieve at least identical therapeutic effects as conventional constant pressure CPAP with a lower mean treatment pressure. The present study was designed to evaluate the therapeutic efficacy and the treatment pressure of an auto-CPAP machine (REM + auto, SEFAM) in comparison with a conventional CPAP device. METHODS Following CPAP titration, 16 patients with OSA were allocated to receive conventional CPAP and auto-CPAP treatment under polysomnographic control in a randomised order. After each treatment the patients were asked to assess the therapy using a questionnaire; a vigilance test was also carried out and subjective daytime sleepiness was evaluated using the Epworth Sleepiness Scale (ESS). RESULTS The mean (SD) apnoea/hypopnoea index (AHI) during auto-CPAP treatment was comparable with that during conventional CPAP treatment (4.2 (5.1) versus 3.6 (4.0)). Neither an analysis of sleep architecture nor the arousal index (7.4 (4.1) versus 7.0 (4.3)) revealed any significant differences. Daytime sleepiness measured with the ESS was also comparable (5.3 (3.4) versus 6.5 (4.2)). The vigilance test showed normal values after both treatments in all patients with no significant differences. The mean pressure during auto-CPAP treatment (8.1 (2.9) mbar), however, was significantly higher than that employed in conventional CPAP treatment (7.6 (2.7) mbar; mean difference 0.5 mbar; 95% CI 0.1 to 0.9 mbar; p < 0.05). CONCLUSIONS Auto-CPAP was equally as effective as conventional CPAP with respect to therapeutic efficacy. The aim of reducing the treatment pressure with auto-CPAP, however, was not achieved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two months follow up of auto-CPAP treatment in patients with obstructive sleep apnoea.

BACKGROUND Continuous positive airway pressure (CPAP) with fixed mask pressure is the current standard treatment for obstructive sleep apnoea (OSA). Auto-CPAP devices apply at any time the minimally required pressure to normalise breathing and may improve patient comfort and compliance. We present an open descriptive study of auto-CPAP treatment at home in patients previously managed with conve...

متن کامل

An auto-continuous positive airway pressure device controlled exclusively by the forced oscillation technique.

The forced oscillation technique (FOT) has been demonstrated to be a very sensitive tool for the assessment of upper airway obstruction during nasal continuous positive airway pressure (CPAP) therapy for obstructive sleep apnoea (OSA). The present study was designed to evaluate the therapeutic efficacy of a novel auto-CPAP device based exclusively on the FOT. Following manual CPAP titration, 18...

متن کامل

Importance of sleep stage- and body position-dependence of sleep apnoea in determining benefits to auto-CPAP therapy.

The influence of sleep stage- and body position-dependence of sleep apnoea on treatment efficacy and compliance between conventional continuous positive airway pressure (CPAP) and auto CPAP therapy was evaluated. Thirty-three newly treated sleep apnoea hypopnoea syndrome (SAHS) patients were randomly allocated to conventional or auto-CPAP therapy. Six patients of each treatment group were class...

متن کامل

Comparison of three auto-adjusting positive pressure devices in patients with sleep apnoea.

Auto-adjustable continuous positive airway pressure (APAP) devices are an emerging treatment alternative to fixed-pressure continuous positive airway pressure (CPAP) therapy for obstructive sleep apnoea syndrome. They have been engineered to automatically adjust the pressure to the optimal level on a continuous basis. However, not all APAP technologies use the same algorithm. Three different AP...

متن کامل

Auto-adjusting versus fixed positive pressure therapy in mild to moderate obstructive sleep apnoea.

STUDY OBJECTIVES To determine if auto-adjusting positive airway pressure (APAP) would be better tolerated on the basis of delivering a lower mean pressure in patients with mild to moderate obstructive sleep apnoea syndrome (OSAS). DESIGN Patients spent 8 weeks on continuous positive airway pressure (CPAP) and 8 weeks on APAP in a randomized crossover design. SETTING Respiratory Sleep Disord...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 53 8  شماره 

صفحات  -

تاریخ انتشار 1998