Visual enhancement of laparoscopic partial nephrectomy with 3-charge coupled device camera: assessing intraoperative tissue perfusion and vascular anatomy by visible hemoglobin spectral response.
نویسندگان
چکیده
PURPOSE We report the novel use of 3-charge coupled device camera technology to infer tissue oxygenation. The technique can aid surgeons to reliably differentiate vascular structures and noninvasively assess laparoscopic intraoperative changes in renal tissue perfusion during and after warm ischemia. MATERIALS AND METHODS We analyzed select digital video images from 10 laparoscopic partial nephrectomies for their individual 3-charge coupled device response. We enhanced surgical images by subtracting the red charge coupled device response from the blue response and overlaying the calculated image on the original image. Mean intensity values for regions of interest were compared and used to differentiate arterial and venous vasculature, and ischemic and nonischemic renal parenchyma. RESULTS The 3-charge coupled device enhanced images clearly delineated the vessels in all cases. Arteries were indicated by an intense red color while veins were shown in blue. Differences in mean region of interest intensity values for arteries and veins were statistically significant (p >0.0001). Three-charge coupled device analysis of pre-clamp and post-clamp renal images revealed visible, dramatic color enhancement for ischemic vs nonischemic kidneys. Differences in the mean region of interest intensity values were also significant (p <0.05). CONCLUSIONS We present a simple use of conventional 3-charge coupled device camera technology in a way that may provide urological surgeons with the ability to reliably distinguish vascular structures during hilar dissection, and detect and monitor changes in renal tissue perfusion during and after warm ischemia.
منابع مشابه
Non-invasive monitoring of tissue oxygenation during laparoscopic donor nephrectomy
BACKGROUND Standard methods for assessment of organ viability during surgery are typically limited to visual cues and tactile feedback in open surgery. However, during laparoscopic surgery, these processes are impaired. This is of particular relevance during laparoscopic renal donation, where the condition of the kidney must be optimized despite considerable manipulation. However, there is no i...
متن کاملA Feasible Technique for Transient Vascular Occlusion by Using a Vessel Loop and Hem-o-Lok Clips in Laparoscopic Partial Nephrectomy
PURPOSE We introduce our transient vascular occlusion technique that uses a vessel loop and Hem-o-Lok clips in laparoscopic partial nephrectomy. MATERIALS AND METHODS From March 2009 to March 2011, 15 consecutive patients underwent laparoscopic partial nephrectomy. All operations were performed by a single surgeon using the transperitoneal approach. The transient vascular occlusion technique ...
متن کاملComparison of Laparoscopic Versus Conventional Open Partial Nephrectomy in Dogs
Objective- Laparoscopic partial nephrectomy (LPN) has been proven to be a safe and effective technique in human. This study was conducted to evaluate the feasibility and safety of utilizing laparoscopic partial nephrectomy in dogs and to compare this technique with open routine partial nephrectomy for the first time in Iran. Design- Experimental study. Animals- Sixteen large mixed-breed femal...
متن کاملEvidence of a heterogeneous tissue oxygenation: renal ischemia/reperfusion injury in a large animal model.
Renal ischemia that occurs intraoperatively during procedures requiring clamping of the renal artery (such as renal procurement for transplantation and partial nephrectomy for renal cancer) is known to have a significant impact on the viability of that kidney. To better understand the dynamics of intraoperative renal ischemia and recovery of renal oxygenation during reperfusion, a visible refle...
متن کاملIn-House Handmade Camera for Indocyanine Green Video Angiography
Background and Aim: Vascular imaging during surgical procedures is very important and has many applications. There are several methods for intraoperative vascular assessment such as intraoperative angiography, Doppler, and fluorescence-based techniques. The latter group and specially the Indocyanine Green (ICG) Video Angiography (VA) is commonly used for vascular surgery and sentinel node...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of urology
دوره 184 4 شماره
صفحات -
تاریخ انتشار 2010