Assessment of space proton radiation-induced charge transfer inefficiency in the CCD204 for the Euclid space observatory

نویسندگان

  • J. P. D. Gow
  • N. J. Murray
  • A. D. Holland
  • D. J. Hall
  • M. Cropper
  • D. Burt
  • G. Hopkinson
  • L. Duvet
چکیده

Euclid is a medium class European Space Agency mission candidate for launch in 2019 with a primary goal to study the dark universe using the weak lensing and baryonic acoustic oscillations techniques. Weak lensing depends on accurate shape measurements of distant galaxies. Therefore it is beneficial that the effects of radiation-induced charge transfer inefficiency (CTI) in the Euclid CCDs over the course of the 5 year mission at L2 are understood. This will allow, through experimental analysis and modelling techniques, the effects of radiation induced CTI on shape to be decoupled from those of mass inhomogeneities along the line-of-sight. This paper discusses a selection of work from the study that has been undertaken using the e2v CCD204 as part of the initial proton radiation damage assessment for Euclid. The experimental arrangement and procedure are described followed by the results obtained, thereby allowing recommendations to be made on the CCD operating temperature, to provide an insight into CTI effects using an optical background, to assess the benefits of using charge injection on CTI recovery and the effect of the use of two different methods of serial clocking on serial CTI. This work will form the basis 1Corresponding author. c © 2012 IOP Publishing Ltd and SISSA doi:10.1088/1748-0221/7/01/C01030 2 0 1 2 J I N S T 7 C 0 1 0 3 0 of a comparison with a p-channel CCD204 fabricated using the same mask set as the n-channel equivalent. A custom CCD has been designed, based on this work and discussions between e2v technologies plc. and the Euclid consortium, and designated the CCD273.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of proton radiation-induced charge transfer inefficiency in the CCD273 detector for the Euclid Dark Energy Mission

Euclid is a medium class mission selected for launch in 2019, with a primary goal to study the dark universe using the weak lensing and baryonic acoustic oscillations techniques. Weak lensing depends on accurate shape measurements, therefore it is beneficial that the effects of radiation-induced charge transfer inefficiency (CTI) in the Euclid CCD over the six year mission are understood and mi...

متن کامل

Challenges in photon-starved space astronomy in a harsh radiation environment using CCDs

The Charge Coupled Device (CCD) has a long heritage for imaging and spectroscopy in many space astronomy missions. However, the harsh radiation environment experienced in orbit creates defects in the silicon that capture the signal being transferred through the CCD. This radiation damage has a detrimental impact on the detector performance and requires carefully planned mitigation strategies. T...

متن کامل

Mitigating Radiation-Induced Charge Transfer Inefficiency in Full- Frame CCD Applications by ‘Pumping’ Traps

The charge transfer efficiency of a CCD is based on the average level of signal lost per pixel over a number of transfers. This value can be used to directly compare the relative performances of different structures, increases in radiation damage or to quantify improvements in operating parameters. This number does not however give sufficient detail to mitigate for the actual signal loss/defere...

متن کامل

Optimisation of device clocking schemes to minimise the effects of radiation damage in Charge Coupled Devices

The ESA Euclid mission aims to answer the question of how the universe originated through the mapping of the dark Universe. One method to investigate this geometry is to measure subtle changes in ellipticity using image sensors such as the CCD. However, the radiation environment in space plays a major part in the performance of CCD-based camera systems. When placed in space, a CCD becomes damag...

متن کامل

Modelling charge transfer in a radiation damaged Charge Coupled Device for Euclid

As electrons are transferred through a radiation damaged Charge Coupled Device (CCD), they may encounter traps in the silicon in which they will be captured and subsequently released. This capture and release of electrons can lead to a ‘smearing’ of the image. The dynamics of the trapping process can be described through the use of Shockley-Read-Hall theory, in which exponential time constants ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016