A new technique to examine individual pollutant particle and fibre deposition and transit behaviour in live mouse trachea.

نویسندگان

  • Martin Donnelley
  • Karen K W Siu
  • Kaye S Morgan
  • William Skinner
  • Yoshio Suzuki
  • Akihisa Takeuchi
  • Kentaro Uesugi
  • Naoto Yagi
  • David W Parsons
چکیده

During respiration, particles suspended in the air are inhaled and unless cleared by airway defences they can remain and affect lung health. Their size precludes the use of standard imaging modalities so we have developed synchrotron phase-contrast X-ray imaging (PCXI) methods to non-invasively monitor the behaviour of individual particles in live mouse airways. In this study we used these techniques to examine post-deposition particle behaviour in the trachea. PCXI was used to monitor the deposition and subsequent behaviour of particles of quarry dust and lead ore; fibres of asbestos and fibreglass; and hollow glass micro-spheres. Visibility was examined in vitro and ex vivo to avoid the complicating effects of surrounding tissue and respiratory or cardiac motion. Particle behaviour was then examined after deposition onto the tracheal airway surfaces of live mice. Each particle and fibre looked and behaved differently on the airway surface. Particles lodged on the airway shortly after deposition, and the rate at which this occurred was dependent on the particle type and size. After the live-imaging experiments, excised airway samples were examined using light and electron microscopy. Evidence of particle capture into the airway surface fluids and the epithelial cell layer was found. PCXI is a valuable tool for examining post-deposition particulate behaviour in the tracheal airway. These first indications that the interaction between airways and individual particles may depend on the particle type and size should provide a novel approach to studying the early effects of respired particles on airway health.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MULTI FRACTURE/DELAMINATION ANALYSIS OF COMPOSITES SUBJECTED TO IMPACT LOADINGS

A combined finite/ discrete element method is presented for modelling of composite specimens subjected to dynamic/impact loadings. The main task is set on developing an algorithm for simulation of potential bonding and debonding/delamination phenomena during impact or general dynamic loading conditions. In addition, full fracture analysis can also be performed. The proposed approach adopts a ge...

متن کامل

Designing and Creating a Mouse Using Nature-Inspired Shapes

Human beings have always made their tools and instruments they need using patterns in nature. Mimicking nature has become the foundation of a new science called Biomimetics. In the present article, multiple forms and levels in nature were utilized to design and create a mouse. The rivers are a good source for choosing the shape of a mouse with lots of stones abraded through the centuries which ...

متن کامل

Particle deposition in the trachea: in vivo and in hollow casts.

The pattern of deposition within the respiratory tract of potentially harmful particulates is a major factor in assessing any risk from individual and community exposures. Although the trachea is the most easily observed of the conductive airways, very little information concerning its particle collection characteristics is available, information which is essential for a complete and realistic ...

متن کامل

Micro Particles Transport and Deposition in Realistic Geometry of Human Upper Airways

Realistic geometry of human upper airways from mouth to the end of trachea was reconstructed by implementing the CT-Scan images of a male subject.   A computational model for analyzing the airflow in the airways was developed and several simulations were performed.  To capture the anisotropy of the inhaled airflow in the upper airways, the Reynolds stress transport model of turbulence was used ...

متن کامل

Calculation of 99mTc-DTPA transit times in normal kidney [Persian]

Introduction: Renal dynamic study is a well-established and popular test in routine practice of nuclear medicine. The test is non-invasive, rapid and unique in evaluation of the kidney function. In despite of its clinical values, the parameters derived from renogram are physiologically meaningless. That is due to the fact that renogram is not the true kidney function. From mathematical po...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of synchrotron radiation

دوره 17 6  شماره 

صفحات  -

تاریخ انتشار 2010