Temperature rise of alveolar bone during dental implant drilling using the finite element simulation
نویسندگان
چکیده
In this study, a three-dimensional elastic-plastic dynamic finite element model is used to simulate the alveolar bone temperature rise during dental implant drilling. An experimental setup was designed to verify the feasibility of the proposed dynamic finite element model. The peak bone temperature within the alveolar bone is investigated through both simulations and experiments. The results indicate that the proposed elastic-plastic dynamic finite element model can provide a good prediction of the alveolar bone temperature rise during the implant drilling. The result also indicated that the peak bone temperature occurs at the interface of cortical bone and cancellous bone for a fixed feeding rate. [Life Science Journal. 2010; 7(1): 68 – 72] (ISSN: 1097 – 8135).
منابع مشابه
FEM investigation of drilling conditions on heat generation during teeth implantation
Abstract The first step of implanting teeth is to drill a hole in the jaw bone. Excessive temperature produced during drilling is one of the destructive factors for bony tissue. If the temperature generation during surgical drilling exceeds the critical temperature, it could lead to osteonecrosis. This research intends to study drilling parameters such as drilling speed, feed rate, cooling con...
متن کاملEvaluating the impact of length and thread pitch on the stress distribution in dental implants and surrounding bone using finite element method
longevity of osseointegrated implants are intensely influenced by biomechanical factors. Control of these factors prevents mechanical complications, which include fracture of screws, components, or materials veneering the framework. In this study, the impact of length and threads pitch of dental implants on the stress distribution and maximum Von Mises stress in implant-abutment complex and ja...
متن کاملEffects of a drill diameter on the temperature rise in a bone during implant site preparation under clinical conditions.
Heat, generated during the drilling of a dental implant site preparation, leads to a temperature rise and consequently to a thermal injury of the bone tissue surrounding the implant site, which can cause the subsequent implant failure. In this article, we present new findings related to the temperature rise during implant site drilling under real conditions on a bovine rib bone specimen. The ex...
متن کاملA Comparison of Heat Generation in Different Depths of Implant Drilling Site with and without a Sleeve
Introduction: The purpose of this study was to compare the heat generated from different depths of an implant drilling site with and without a sleeve. Materials and methods: In this study, 60 cortical bone samples were used and a load of 2.0 kg was applied. rilling for implant surgery, we used a diameter of 4.3 mm and a normal sleeve. Heat was measured from 3 different depths(3,6, an...
متن کاملمقایسه بیومکانیکی ایمپلنت دندانی تیتانیوم خالص با زیرکونیوم -5/2% نایوبیوم پس از کاشت به روش اجزای محدود
Background and Aims: Improving dental implantation conditions in order to reduce the failure is always desirable for researchers. The aim of this study was to compare two different materials of dental implants from the viewpoint of biomechanical effect after placement and loading in the mandible. Materials and Methods: A 3D model of mandible was designed in the MIMICS 10.01 software. Then,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2010