An in vitro comparative study to evaluate the retention of different attachment systems used in implant-retained overdentures
نویسندگان
چکیده
AIM The aim of this in vitro study was to compare the change in the retentive force and removal torque of three attachment systems during simulation of insertion-removal cycles. METHODOLOGY Edentulous mandibular models were made with heat-cured polymethyl methacrylate resin. Two implant replicas (CMI), of 3.75 mm diameter and 10 mm length, were placed in the intraforaminal region. Acrylic resin mandibular overdentures were fabricated and provision was made to receive three different overdenture attachment systems, prefabricated ball/o-ring attachment (Lifecare Biosystems, Thane, India), Hader bar and clip attachment (Sterngold, Attleboro, MA), and Locator(®) implant overdenture attachment stud type (Zest Anchors LLC, USA). Using a universal testing machine, each of the models were subjected to 100 pulls each to dislodge the overdenture from the acrylic model, and the force values as indicated on the digital indicator were tabulated both before and after thermocycling (AT). STATISTICAL ANALYSIS USED Statistical analysis comprised Kolmogorov-Smirnov test, Friedman test, and Wilcoxon signed ranks test. RESULTS The statistical model revealed a significantly different behavior of the attachment systems both before and AT. The ball/o-ring and bar attachments developed higher retentive force as compared to the locator attachment. The bar and clip attachment exhibited the highest peak as well as the highest mean retention force at the end of the study. The Locator(®) attachment showed a decrease in retentive potential after an early peak. CONCLUSIONS AND CLINICAL IMPLICATIONS The ball/o-ring and bar and clip attachments exhibit higher retentive capacities than the Locator(®) attachment over time.
منابع مشابه
Comparison of the Effect of Ball and Bar Attachment Designs on Retention and Stability of Mandibular Implant-Supported Overdentures
Objectives: The present study evaluated the effect of bar and ball attachment designs on retention and stability of a mandibular overdenture supported by four implants. Methods: An edentulous mandibular acrylic resin model with four implants in the anterior part of the ridge (A, B, D and E) was fabricated. A metal framework simulating the overdenture was also fabricated. Totally, 30...
متن کاملComparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity
Comparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity Dr. A. Saboori* - Dr. Gh. Esfahanizade** - Dr. M. Ejlali*** *- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Shaheed Beheshti University of Medical Sciences. **- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Tehran Isl...
متن کاملComparison of retention and stability of two implant-retained overdentures based on implant location.
STATEMENT OF PROBLEM The location of dental implants and the choice of retentive attachments for implant-retained overdentures are selected based on clinician preference, expert opinion, or empirical information. Limited information is available regarding implant position and the effect on the retention and stability of 2-implant mandibular implant overdentures. PURPOSE The purpose of this in...
متن کاملThe Effect of Inter-Implant Distance on Retention and Resistance to Dislodging Forces for Mandibular Implant-Tissue-Supported Overdentures
OBJECTIVES The effect of inter-implant distance on retention and resistance of implant-tissue-supported overdentures is lacking in the literature. An in vitro study was performed to evaluate this effect for mandibular implant-tissue-supported overdentures retained by two ball attachments. MATERIALS AND METHODS An acrylic cast of an edentulous mandible was fabricated. Three pairs of implants w...
متن کاملIn vitro retention force measurement for three different attachment systems for implant-retained overdenture
AIM The aim of this study is to compare the retention force of three different types of overdenture attachment systems used in implant-retained mandibular complete overdentures. MATERIALS AND METHODS Twenty-one similar acrylic resin blocks were prepared and divided into three study groups: Group A (snap attachment) - 10 specimens, Group B (locator attachment) - 1 specimen, and Group C (syncon...
متن کامل