Deformations and cyclic fatigue resistance of nickel-titanium instruments inside a sequence.
نویسندگان
چکیده
AIM To compare the effect of brushing motion on torsional and cyclic fatigue resistance of TF Adaptive instruments after clinical use. METHODS 20 packs of TFA small sequence (SybronEndo, Orange, CA, USA) were used for this study and divided into two groups. Each instrument prepared one resin tooth, consisting in 4 canals with a complex anatomy. In group A, no brushing motion was performed. In group B, after the green instrument reached the working length, brushing motion with circumferential filing was performed for 15 seconds in each canal (overall 1 minute). All the instruments were then subjected to cyclic fatigue test and mean values and standard deviation for time to fracture were evaluated. Data were subjected to one-way analysis of variance and Bonferroni t-test procedure with a significance set at P < 0.05. RESULTS No instruments were broken during preparation of root canals. Two TF Adaptive green and 5 yellow showed unwinding after intracanal clinical use. No statistically significant differences were found between green instruments of both groups (P > 0.05), while a statistically significant difference was found between the yellow instruments (P < 0.05), with group B showing an higher resistance to cyclic fatigue. CONCLUSIONS A prolonged passive brushing motion did not adversely affected mechanical resistance of the instrument used for this purpose. Resistance to both deformations and cyclic fatigue of the second instrument within the TFA small sequence was enhanced by the coronal flaring provided by the brushing action of the first instrument used.
منابع مشابه
Cyclic Fatigue of Different Nickel-Titanium Rotary Instruments: A Comparative Study
Since the introduction of nickel-titanium alloy to endodontics, there have been many changes in instrument design, but no significant improvements in the raw material properties, or enhancements in the manufacturing process. Recently, a new method to produce nickel-titanium rotary (NTR) instruments has been developed, in an attempt to obtain instruments that are more flexible and resistant to f...
متن کاملEffect of clinical use on the cyclic fatigue resistance of ProTaper nickel-titanium rotary instruments.
The resistance of ProTaper (Dentsply Maillefer, Ballaigues, Switzerland) nickel-titanium rotary instruments to cyclic fatigue was examined after their initial use in straight or curved canals in vivo. These instruments were rotated freely inside a steel phantom until separation. The number of rotations before failure and the lengths of the separated fragments were compared with data derived fro...
متن کاملInfluence of file motion on cyclic fatigue of new nickel titanium instruments.
AIM The aim of the present study was to compare the resistance to cyclic fatigue of Hyflex® (Coltene-Whaledent, Allstatten, Switzerland) size 40 taper.04 nickel titanium instruments used in continuous rotation versus the use with a reciprocating motion. The null hypothesis was that different file motions had no influence on the lifetime of instruments subjected to a cyclic fatigue test. METHO...
متن کاملCyclic fatigue and torsional resistance of two new nickel - titanium instruments used in reciprocation motion : Reciproc Versus
The use of reciprocating movement (RM) was claimed to increase the resistance of nickel-titanium (NiTi) file to fatigue in comparison to continuous rotation (CR). Recently two new brands of NiTi file have been marketed for use in a RM mode. The purpose of this study was to compare the cyclic fatigue resistance and torsional resistance of these two files; Reciproc and WaveOne. Cyclic fatigue tes...
متن کاملTorsion Property and Cyclic Fatigue Fracture Behavior of Nickel-Titanium Endodontic Instruments
The torsion property and rotary fatigue fracture behavior of Smart K file and R reamer made of nickel titanium alloy have been studied by means of Shimadzu Autograph DDS-10T universal tester and man-made cyclic system with curved copper tubes as simulated root canal. The instrument surface and the cyclic fatigue fracture surface have been investigated by optical microscope and scanning electro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annali di stomatologia
دوره 6 1 شماره
صفحات -
تاریخ انتشار 2015