Significant increase in the incidence of ventricular arrhythmic events after an intrathoracic impedance change measured with a cardiac resynchronization therapy defibrillator.
نویسندگان
چکیده
BACKGROUND Cardiac resynchronization therapy defibrillator (CRT-D) devices are now capable of monitoring changes in intrathoracic impedance. Intrathoracic impedance monitoring resulting in a fluid index threshold crossing has been proven to predict heart failure (HF) exacerbations. We retrospectively investigated the relationship between changes in intrathoracic impedance and the occurrence of arrhythmic events. METHODS AND RESULTS From 282 patients with New York Heart Association class III or IV HF who were implanted with a CRT-D device with a fluid index feature based on intrathoracic impedance monitoring capabilities, arrhythmic events were retrospectively analyzed in terms of the threshold crossings. The patients were divided into 2 groups: those with fluid index threshold crossings and those without threshold crossings. A total of 4,725 tachyarrhythmic events were reported in 129 patients (46%), and there were 221 fluid index crossing events in 145 patients (51%) during 10.0 ± 3.2 months. Tachyarrhythmic events were more frequently recorded in patients with threshold crossing events than in those who did not experience a threshold crossing (3,241 vs. 1,484 events, P<0.0001). Ventricular tachyarrhythmic events mainly occurred within the first 30 days after the threshold crossing event; however, a similar trend was not observed for the atrial tachyarrhythmic events. CONCLUSIONS Intrathoracic impedance monitoring may predict arrhythmic events, especially ventricular arrhythmias, in patients with HF and provides an additional management tool.
منابع مشابه
Decreased Intrathoracic Impedance Associated With OptiVol Alert Can Diagnose Increased B-Type Natriuretic Peptide
indicators even with day-to-day follow-up of patients with HF.3,4 Daily monitoring of the thoracic fluid status with intrathoracic impedance (ITI) is a diagnostic feature of implantable cardioverter defibrillators (ICD) or can be carried out in combination with cardiac resynchronization therapy (CRT-D). The monitoring of ITI may provide helpful information for the early detection of HF decompen...
متن کاملMaking a Splash?
ver the past decade, implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy (CRT) device platforms have been expanded to include a host of new integrated device-based diagnostic capabilities.1 Parameters such as a sustained drop in intrathoracic impedance, reduced heart rate variability, high resting heart rate, decreased patient activity, prolonged periods of atrial...
متن کاملVentricular arrhythmias in super-responders to cardiac resynchronization therapy.
INTRODUCTION AND OBJECTIVES Cardiac resynchronization therapy is associated with improved quality of life and reduced morbidity and mortality in patients with severe ventricular dysfunction and wide QRS. However, its role in the reduction of ventricular arrhythmias is more controversial. METHODS We compared the incidence of ventricular arrhythmias in patients who were undergoing cardiac resyn...
متن کاملA case of premature ventricular contractions, ventricular tachycardia, and arrhythmic storm induced by right ventricular pacing during cardiac resynchronization therapy: Electrophysiological mechanism and catheter ablation.
A 77-year-old man with ischemic cardiomyopathy and a cardiac resynchronization therapy-defibrillator (CRT-D) device came to our attention due to incessant ventricular tachycardia and multiple implantable cardioverter defibrillator (ICD) shocks. An electrocardiogram showed non-sustained monomorphic ventricular tachycardias (NSVTs) constantly occurring after each biventricular stimulation. During...
متن کاملOptiVol fluid index predicts acute decompensation of heart failure with a high rate of unexplained events
BACKGROUND Intrathoracic impedance monitoring has emerged as a promising new technique for the detection of impending heart failure (HF). Although false positive episodes have been reported in case reports and clinical trials, the efficacy and false positive rate in real-world practice remain unclear. OBJECTIVE The aim of this study is to investigate the utility and reliability of the OptiVol...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation journal : official journal of the Japanese Circulation Society
دوره 75 11 شماره
صفحات -
تاریخ انتشار 2011