Comparison of 2D and 3D Gamma calculations for an IMRT QA phantom
نویسندگان
چکیده
Gamma index pass rates were evaluated for an anthropomorphic phantom using both 2D and 3D calculations. The phantom was irradiated with the traditional dosimetry insert loaded with radiochromic film and TLD, and then with a 3D dosimetry insert. A comparison with the calculated dose distribution showed that both the PRESAGE ® dosimeter and the film and TLD system agreed with the plan to within 5% using 2D gamma index criteria. The 3D gamma index showed a slightly higher pass rate than the 2D gamma index at 3%/3mm, and comparable pass rates using more generous constraints. The acceptable number of pixels passing the tighter constraints (3%/3mm) might be dependent upon the choice between a 2D calculation versus a 3D calculation. 1. Background The ability for 3D dosimetry to obtain a large amount of data in a single irradiation is advantageous [1]. The benefits have led us to consider outfitting the Imaging and Radiation Oncology Core (IROC formerly the RPC) anthropomorphic phantoms with 3D dosimeters. The phantoms currently use film and TLD; we propose to use PRESAGE dosimeters [2]. In doing so, we must also look at how we will evaluate the data. Currently, 2D gamma calculations from film measurements are the IROC standard for evaluating an irradiation. Moving to a 3D dosimeter would allow for a 3D gamma calculation and true volumetric quality assurance. The extra dimension while searching for agreement in a gamma calculation should produce a higher pass rate when compared to a 2D gamma calculation using the same criteria [3, 4]. This study investigated gamma pass rates for identification of appropriate constraints for quality assurance evaluation. 2. Methods An IROC head and neck (H&N) phantom was fitted with a cylindrical insert to hold a 500 g cylinder of PRESAGE ® . The original IROC insert contained radiochromic film in the axial and sagittal planes and 8 TLD capsules. The PRESAGE insert covered the same volume as the structures and dosimeters in the original phantom. Both inserts are shown in figure 1. 8th International Conference on 3D Radiation Dosimetry (IC3DDose) IOP Publishing Journal of Physics: Conference Series 573 (2015) 012055 doi:10.1088/1742-6596/573/1/012055 Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. Published under licence by IOP Publishing Ltd 1 Figure 1. (A) Phantom with Film/TLD insert. Two PTVs and an organ at risk are contoured. (B) Phantom with PRESAGE ® insert. A 9-beam IMRT plan was developed with a Pinnacle planning system (Philips Radiation Oncology Systems, Fitchburg, WI) for delivery with a Varian linear accelerator (Varian Medical Systems, Palo Alto, CA). The phantom containing the film/TLD insert was irradiated 3 times, then the phantom containing PRESAGE was irradiated an additional 3 times. The film and TLD were evaluated according to the IROC standard procedures for the H&N phantom described by Molineu et. al. [5]. The PRESAGE ® dosimeters were scanned using the Duke Midsized Optical Scanner for IROC (DMOS-IROC) using a 1 mm voxel edge for reconstruction. Change in optical density (OD) was measured by subtracting pre-irradiation scans from post-irradiation scans [6]. The dose was imported into the Computational Environment for Radiotherapy Research (CERR) for evaluation [7]. The film and PRESAGE measured doses were scaled to the mean TLD dose at relevant locations and 2D gamma calculations were made in the axial and sagittal planes bisecting the primary target for the film and the PRESAGE. 3D gamma measurements excluded the outermost 5 mm of each PRESAGE dosimeter to eliminate edge artifacts. Gamma constraints of 3%/3mm distance to agreement (DTA), 5%/3mm DTA and 7%/4mm DTA were used in the study. The gamma-index analyses for the 3 irradiations for each insert were averaged together for comparison. 3. Results The average pass rate from the 2D gamma calculations for each trial is shown in table 1. The results from a 3D gamma over the full volume are shown in table 2. Table 1. Average 2D gamma pass rates Constraints Film PRESAGE ® Axial Plane 3%/3mm 85% 85% 5%/3mm 93% 94% 7%/4mm 99% 97% Sagittal Plane 3%/3mm 85% 89% 5%/3mm 90% 95% 7%/4mm 99% 99% Table 2. Average 3D gamma pass rates Constraints PRESAGE ® 3%/3mm 90% 5%/3mm 95% 7%/4mm 99% 8th International Conference on 3D Radiation Dosimetry (IC3DDose) IOP Publishing Journal of Physics: Conference Series 573 (2015) 012055 doi:10.1088/1742-6596/573/1/012055
منابع مشابه
مقایسه عملکرد فیلم گف کرومیک EBT3و فانتوم Delta4® در تکنیک IMRT محیط ناهمگن قفسه سینه
Introdution: In advanced radiotherapy techniques such as intensity modulated radiation therapy (IMRT), the quality assurance (QA) is essential. This study aimed to compare the performance between GafchromicTM EBT3 film and Delta4® phantom (2D and 3D) in heterogeneous chest phantom using IMRT technique. Methods: In this experimental study, two IMRT plans (A and B) were prepared for radiothe...
متن کاملEvaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT
Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...
متن کاملThe use of EBT3 film and Delta4 for the dosimetric verification of EclipseTM treatment planning system in a heterogeneous chest phantom: an IMRT technique
Background: This study aimed to evaluate the dose calculation accuracy of EclipseTM treatment planning system (TPS) in a heterogeneous chest phantom with the intensity modulated radiotherapy (IMRT) technique using EBT3 film and Delta4. Materials and Methods: Two IMRT plans (A and B) were prepared for radiotherapy of the heterogeneous chest phantom. Plan A was between the left lung and the surro...
متن کاملComparison between two different methods used for IMRT plans QA of Prostate cancer
Introduction: The aim of this study is evaluation of two Quality Assurance methods in sliding window IMRT technique and Determination of gamma index in both methods Materials and Methods: In this study two tools named" Delta4" phantom and " Epiqa" software has been used to perform QA on the treatment plan before the actual treatment by Varian linear acceler...
متن کاملComparison of 3D anatomical dose verification and 2D phantom dose verification of IMRT/VMAT treatments for nasopharyngeal carcinoma
BACKGROUND The two-dimensional phantom dose verification (2D-PDV) using hybrid plan and planar dose measurement has been widely used for IMRT treatment QA. Due to the lack of information about the correlations between the verification results and the anatomical structure of patients, it is inadequate in clinical evaluation. A three-dimensional anatomical dose verification (3D-ADV) method was us...
متن کامل