SEM Analysis and Management of Fracture Dental Implant

نویسندگان

  • Archana Singh
  • Ankita Singh
  • Rajul Vivek
  • T. P. Chaturvedi
  • Pankaj Chauhan
  • Shruti Gupta
چکیده

Implant fracture is one of the important biomechanical complications which can present with a considerable problem to the patient as well as the dental surgeon. The aim of this case report is to describe the management of a case of fractured endosseous dental implant in premolar region and microscopic evaluation of the fractured implant segment using scanning electron microscopy. In most of such cases, complete removal of the fractured implant has been a preferred treatment option. In the present case, fractured implant segment was successfully removed and rehabilitated immediately with larger diameter implant. It was found that retrieved fracture segment had a diameter of 3.3 mm, and SEM analysis shows fatigue fractures which may be the result of excessive overloading and use of small diameter implant which enhances fatigue failure.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating the Frequency of Implant-Supported Fixed Prosthesis Complications in Yazd Dental School in 2020

Introduction: Evaluating the frequency of complications in implant supported prosthesis such as screw loosening and porcelain fracture is important for prevention and management of these problems. The purpose of this study was to evaluate the frequency of implant-supported fixed prosthesis complications in Yazd dental school  in 2020. Methods: In this descriptive cross-sectional study, the pat...

متن کامل

Clinical management and microscopic characterisation of fatique-induced failure of a dental implant. Case report

BACKGROUND Osseointegrated endosseous implants are widely used for the rehabilitation of completely and partially edentulous patients, being the final prosthodontic treatment more predictable and the failures extremely infrequent. A case of fracture of an endosseous dental implant, replacing the maxillary first molar, occurring in a middle-age woman, 5 years after placement is reported. MATER...

متن کامل

Management of a Congenitally Missing Lateral Incisor with Orthodontics, Bone Grafting (a New Method) and Single-Tooth Implant: A Case Report

Careful treatment planning, space management, augmentation of bone and attention to the details of implant surgical and prosthetic techniques are important factors when treating anterior maxilla specially replacement of missing teeth. This case report addresses a chair-side ridge augmentation procedure using autograft bone harvested with trephine drills and placed without using screws and the f...

متن کامل

Nonsurgical prosthetic management of mandibular fracture associated with dental implant therapy: a case report.

Mandibular fractures in association with the insertion of endosseous dental implants have been reported in the literature. In this clinical case report, the nonsurgical management of a mandibular fracture with the use of a bar restoration is described and a 3-year follow-up is presented. The options for nonsurgical treatment are discussed.

متن کامل

Evaluating the impact of length and thread pitch on the stress distribution in dental implants and surrounding bone using finite element method

 longevity of osseointegrated implants are intensely influenced by biomechanical factors. Control of these factors prevents mechanical complications, which include fracture of screws, components, or materials veneering the framework. In this study, the impact of length and threads pitch of dental implants on the stress distribution and maximum Von Mises stress in implant-abutment complex and ja...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2013  شماره 

صفحات  -

تاریخ انتشار 2013