A self-paced intermittent protocol on a non-motorised treadmill: a reliable alternative to assessing team-sport running performance.

نویسندگان

  • Paul J Tofari
  • Blake D McLean
  • Justin Kemp
  • Stuart Cormack
چکیده

This study assessed the reliability of a 'self-paced' 30-min, team-sport running protocol on a Woodway Curve 3.0 non-motorised treadmill (NMT). Ten male team-sport athletes (20.3 ± 1.2 y, 74.4 ± 9.7 kg, VO2peak 57.1 ± 4.5 ml·kg(-1)·min(-1)) attended five sessions (VO2peak testing + familiarisation; four reliability trials). The 30-min protocol consisted of three identical 10-min activity blocks, with visual and audible commands directing locomotor activity; however, actual speeds were self-selected by participants. Reliability of variables was estimated using typical error ± 90% confidence limits expressed as a percentage [coefficient of variation (CV)] and intraclass correlation coefficient. The smallest worthwhile change (SWC) was calculated as 0.2 × between participant standard deviation. Peak/mean speed and distance variables assessed across the 30-min protocol exhibited a CV < 5%, and < 6% for each 10-min activity block. All power variables exhibited a CV < 7.5%, except walking (CV 8.3-10.1%). The most reliable variables were maximum and mean sprint speed (CV < 2%). All variables produced a CV% greater than the SWC. A self-paced, team-sport running protocol performed on a NMT produces reliable speed/distance and power data. Importantly, a single familiarisation session allowed for adequate test-retest reliability. The self-paced design provides an ecologically-valid alternative to externally-paced team-sport running simulations. Key pointsSelf-paced team-sport running protocols on a curved NMT that closely match the locomotor demands of competition deliver reliable test-retest measures of speed, distance and power.Such protocols may be sensitive to changes in running profile following an intervention that may not be detectable during externally-paced protocols.One familiarisation session is adequate to ensure test-retest reliability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The reliability of physiological and performance measures during simulated team-sport running on a non-motorised treadmill.

The aim of this study was to determine the reliability of a non-motorised treadmill team-sport simulation for measuring physiological responses and performance demands of team sports. Following familiarisation, 11 team-sport athletes completed a peak sprinting speed assessment followed by a 30-min team-sport simulation on the non-motorised treadmill, on three occasions, 5 days apart. Several pe...

متن کامل

Physical and psychomotor performance of Australian football and rugby league officials during a match simulation.

The onset of exercise facilitates an improvement in psychomotor performance until the second ventilatory threshold, after which performance is reduced. This inverted-U relationship appears valid for incremental and steady-state exercise, however, not for intermittent exercise. This study examined changes in psychomotor performance of team sport officials during a laboratory-based match simulati...

متن کامل

Reliability of a contact and non-contact simulated team game circuit.

Most team sports are characterised by repeated short maximal sprint efforts interspersed with longer periods of active recovery or rest. Although a variety of testing protocols have been devised to simulate these activity patterns under controlled conditions, a common limitation is the lack of 'body contact' to simulate the tackling efforts seen in contact sports. Therefore, the purpose of this...

متن کامل

The influence of caffeine ingestion on strength and power performance in female team-sport players

BACKGROUND The aim of this study was to examine the influence of caffeine supplementation on knee flexor and knee extensor strength before, during and after intermittent running exercise in female team-sport players taking oral contraceptive steroids (OCS). METHOD Ten healthy females (24 ± 4 years; 59.7 ± 3.5 kg; undertaking 2-6 training sessions per week) taking low-dose monophasic oral cont...

متن کامل

The validity of endurance running performance on the Curve 3(TM) non-motorised treadmill.

This study aimed to test the validity of a non-motorised treadmill (NMT) for the measurement of self-paced overground endurance running performance. Ten male runners performed randomised 5-km running time trials on a NMT and an outdoor athletics track. A range of physiological and perceptual responses was measured, and foot strike was classified subjectively. Performance time was strongly corre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of sports science & medicine

دوره 14 1  شماره 

صفحات  -

تاریخ انتشار 2015