Risk factors for hospital mortality in valve replacement with mechanical prosthesis.
نویسندگان
چکیده
OBJECTIVE Identification of risk factors for cardiac surgery can improve surgical results. Our aim is to identify factors related to increased hospital mortality for patients who underwent mechanical cardiac prosthesis implant. METHODS Prospective study with retrospective data acquirement study including 335 consecutive patients who underwent at least one implant of St. Jude Medical mechanical prosthesis between December 1994 and September 2005 at the Cardiology Institute of RS. Valve implants were 158 (47.1%) in aortic position, 146 (43.6%) in mitral and 31 (9.3%) in aortic and mitral. The following characteristics were analyzed in relation to hospital death: gender, age, body mass index, NYHA functional class, ejection fraction, type of valve lesion, hypertension, diabetes mellitus, serum creatinine, preoperative arrhythmias, prior heart surgery, CABG surgery, concomitant tricuspid valve surgery and operative priority (elective, urgent or emergent). Logistical regression was used to analyze data and odds-ratio was calculated for individual factors. RESULTS During the follow-up there were 13 (3.88%) deaths. In-hospital mortality risk was associated with serum creatinine (P<0.05), ejection fraction < 30% (P<0.001), mitral valve lesion (P<0.05), concomitant CABG surgery (P<0.01), prior cardiac surgery (P<0.01) and reoperation (P<0.01). Increased odd-ratio were related to previous cardiac surgery (5.36; IC95% 0.94-30.56), combined revascularization (5.28; IC95% 1.51-18.36), valvar reoperation (4.69; IC95% 0.93-23.57) and concomitant tricuspid annuloplasty (3.72; IC95% 0.75-18.30). CONCLUSION The mortality rate is within the parameters found in the literature, identifying recognized factors which neutralization by changes in surgical indication and medical management may enable risk reduction.
منابع مشابه
عوامل موثر بر علل جراحی مجدد دریچه های مصنوعی قلب و بقاء زودرس بعد عمل، بیمارستان امام، 80-1370
Prosthetic valve re-operation has greater mortality and morbidity than primary valve replacement. By recognition of factors influencing on causes of redo operation and preoperative survival, one can select appropriate prosthesis at primary valve replacement and when operation performed at appropriate time, surgical risk can be reduced.Methods and Materials: Two hundred patients that underwent p...
متن کاملSuccessful Use of Two Thrombolytic Drugs in Prosthetic Mitral and Aortic Valve Thrombosis
Introduction: Prosthetic valve thrombosis is a rare and severe complication of valve replacement, most often encountered with a mechanical prosthesis. The significant morbidity and mortality associated with this condition warrant rapid diagnostic evaluation. Although surgery is the first-line therapy in symptomatic obstructive mechanical valve thrombosis, thrombolytic therapy has been used as a...
متن کاملDouble Valve Replacement (Mitral and Aortic) for Rheumatic Heart Disease: A 20-year experience with 300 patients.
Introduction: Rheumatic heart disease still remains one of the leading causes of congestive heart failure and death owing to valvular pathologies, in developing countries. Valve replacement still remains the treatment of choice in such patients.The aim of this study wasto analyze the postoperative outcome of double valve replacement (Mitral and Aortic ) in patients of rheumatic heart disease. ...
متن کاملAN INNOVATIVE SURGIC AL TECHNIQUE FOR CONTINUOUS SUTURING OF PROSTHESIS IN MITR AL VALVE REPL A CEMENT
Mitral valve replacement (MVR) is usually performed in two methods of running and interrupted suturing. In running method, the suturing of the valve is usually with some traction on the annulus and also there is a risk of aortic valve injury. This study was conducted to evaluate a new technique for suturing to avoid these complications and decrease the time of cardiac arrest. One hundred an...
متن کاملFive-year follow-up after heart valve replacement with the CarboMedics bileaflet prosthesis.
BACKGROUND The CarboMedics valve is a relatively new, low-profile, bileaflet, mechanical prosthesis. The results of a prospective follow-up study after valve replacement with this prosthesis in a university hospital are presented. METHODS We implanted 640 CarboMedics prostheses in 583 patients in the aortic (n = 359), mitral (n = 167), or aortic and mitral positions (double valve replacement;...
متن کاملInfluence of prosthesis type on long-term survival after re-replacement of aortic valve prosthesis.
BACKGROUND The purpose of this study is to examine the influence of the prosthesis type on early mortality and long-term survival after re-replacement of aortic valve prosthesis, especially in patients over 60 years old. METHODS Late outcome of 223 patients who underwent a reoperation on the aortic valve and received a mechanical (mechanical group) or biological (biological group) heart valve...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Revista brasileira de cirurgia cardiovascular : orgao oficial da Sociedade Brasileira de Cirurgia Cardiovascular
دوره 24 3 شماره
صفحات -
تاریخ انتشار 2009