Accuracy of Approximate Inversion Schemes in Quantitative Photacoustic Imaging

نویسندگان

  • Roman Hochuli
  • Paul C. Beard
چکیده

Five numerical phantoms were developed to investigate the accuracy of approximate inversion schemes in the reconstruction of oxygen saturation in photoacoustic imaging. In particular, two types of inversion are considered: Type I, an inversion that assumes fluence is unchanged between illumination wavelengths, and Type II, a method that assumes known background absorption and scattering coefficients to partially correct for the fluence. These approaches are tested in tomography (PAT) and acoustic-resolution microscopy mode (AR-PAM). They are found to produce accurate values of oxygen saturation in a blood vessel of interest at shallow depth less than 3mm for PAT and less than 1mm for AR-PAM.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimized inversion recovery sequences for quantitative T1 and magnetization transfer imaging.

Inversion recovery sequences that vary the inversion time (t(i)) have been employed to determine T(1) and, more recently, quantitative magnetization transfer parameters. Specifically, in previous work, the inversion recovery pulse sequences varied t(i) only while maintaining a constant delay (t(d)) between repetitions. T(1) values were determined by fitting to a single exponential function, and...

متن کامل

Sensitivity of quantitative photoacoustic tomography inversion schemes to experimental uncertainty

The ability to accurately quantify chromophore concentration from photoacoustic images would have a major impact on pre-clinical and clinical imaging. Recent years have seen significant advances in the theoretical understanding of quantitative photoacoustic imaging and in the development of model-based inversion strategies that overcome issues such as non-uniqueness and non-linearity. Neverthel...

متن کامل

A stable iteration to the matrix inversion

The matrix inversion plays a signifcant role in engineering and sciences. Any nonsingular square matrix has a unique inverse which can readily be evaluated via numerical techniques such as direct methods, decomposition scheme, iterative methods, etc. In this research article, first of all an algorithm which has fourth order rate of convergency with conditional stability will be proposed. ...

متن کامل

Comparison of Two Quantitative Susceptibility Mapping Measurement Methods Used For Anatomical Localization of the Iron-Incorporated Deep Brain Nuclei

Introduction Quantitative susceptibility mapping (QSM) is a new contrast mechanism in magnetic resonance imaging (MRI). The images produced by the QSM enable researchers and clinicians to easily localize specific structures of the brain, such as deep brain nuclei. These nuclei are targets in many clinical applications and therefore their easy localization is a must. In this study, we aimed to i...

متن کامل

Theoretical analysis of the effect of imperfect slice profiles on tagging schemes for pulsed arterial spin labeling MRI.

Pulsed arterial spin labeling (ASL) techniques provide a noninvasive method of obtaining qualitative and quantitative perfusion images with MRI. ASL techniques employ inversion recovery and/or saturation recovery to induce perfusion weighting, and thus the performance of these techniques is dependent on the slice profiles of the inversion or saturation pulses. This article systematically examin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014