Non ECG-Triggered Self-Navigated 3D Radial Whole-Heart Cine MRI with High Spatial Resolution for Simultaneous Multi- Phase Coronary and Functional Imaging

نویسندگان

  • Simone Coppo
  • Davide Piccini
  • Gabriele Bonanno
  • Jerome Chaptinel
  • Gabriella Vincenti
  • Matthias Stuber
چکیده

Non ECG-Triggered Self-Navigated 3D Radial Whole-Heart Cine MRI with High Spatial Resolution for Simultaneous MultiPhase Coronary and Functional Imaging. Simone Coppo, Davide Piccini, Gabriele Bonanno, Jerome Chaptinel, Gabriella Vincenti, and Matthias Stuber Center for Biomedical Imaging (CIBM), Lausanne, Switzerland, Radiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland, Advanced Clinical Imaging Technology, Siemens Healthcare IM BM PI, Lausanne, Switzerland, Radiology, University Hospital (CHUV) and University of Lausanne (UNIL)/ Center for Biomedical Imaging (CIBM), Lausanne, Switzerland, Division of Cardiology and Cardiac MR Center, University Hospital (CHUV), Lausanne, Switzerland

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ECG/Navigator-Free 4D Whole-Heart Coronary MRA with Simultaneous Visualization of Cardiac Function and Anatomy

Purpose: Cardiac and respiratory motion artifacts are major challenges in cardiac MRI, and are conventionally suppressed by prospective ECG and diaphragm navigator gating, respectively. However, these approaches require time-consuming setup and prolonged acquisition times, and are susceptible to variations of heart rate or respiratory pattern. Further, they can become unreliable at higher field...

متن کامل

Three-dimensional Whole-Heart Cine MRI using Prospective Self-Gating for Compensation of Cardiac and Respiratory Motion

Introduction: Two-dimensional (2D) breath-hold and ECG-triggered cine MRI is frequently used to assess cardiac function. However this technique requires cooperation from the patient, and the MR acquisition has to be synchronized with the cardiac cycle using ECG. To control respiratory motion, the subject has to perform breath-holds or the position of the diaphragm has to be tracked using a resp...

متن کامل

Dynamic self-navigated 3D whole-heart radial coronary MRA with retrospective acquisition window selection

Background Navigator gated coronary MRA is highly time inefficient as the data collection duty cycle (DC) is only 2% [1]. Here, we report a new, dynamic self-navigated coronary MRA technique with isotropic spatial resolution that a) further improves DC by continuously acquiring image data without ECG triggering and that b) enables retrospective, flexible, and individual selection of the acquisi...

متن کامل

High Spatial and Temporal Resolution 2D Real Time and 3D Whole-Heart Cardiac Cine MRI Using Compressed Sensing and Parallel Imaging with Golden Angle Radial Trajectory

256 3.0 /1.5 256 x 256 39 24 15 High Spatial and Temporal Resolution 2D Real Time and 3D Whole-Heart Cardiac Cine MRI Using Compressed Sensing and Parallel Imaging with Golden Angle Radial Trajectory Li Feng, Jian Xu, Leon Axel, Daniel Sodickson, and Ricardo Otazo Radiology, New York University School of Medicine, New York, New York, United States, Sackler Institute of Graduate Biomedical Scien...

متن کامل

Whole heart self-navigated 3D radial MRI for the creation of virtual 3D models in congenital heart disease

Background Three-dimensional (3D) virtual models are valuable tools that may help to better understand complex cardiovascular anatomy and facilitate surgical planning in patients with congenital heart disease (CHD). Although computed tomography (CT) images are used most commonly to create these models [1,2], Magnetic Resonance Imaging (MRI) may be an attractive alternative, since it offers supe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013