Hyperglycosylated human chorionic gonadotropin (invasive trophoblast antigen) immunoassay: A new basis for gestational Down syndrome screening.

نویسندگان

  • L A Cole
  • S Shahabi
  • U A Oz
  • R O Bahado-Singh
  • M J Mahoney
چکیده

BACKGROUND Serum human chorionic gonadotropin (hCG) and hCG free beta-subunit tests are used in combination with unconjugated estriol and alpha-fetoprotein in the triple screen test, and with the addition of inhibin-A in the quadruple marker test for detecting Down syndrome in the second trimester of pregnancy. These tests have a limited detection rate for Down syndrome: approximately 40% for hCG or free beta-subunit alone, approximately 60% for the triple screen test, and approximately 70% for the quadruple marker test, all at 5%, or a relatively high, false-positive rate. New tests are needed with higher detection and lower false rates. Hyperglycosylated hCG (also known as invasive trophoblast antigen or ITA) is a new test. It specifically detects a unique oligosaccharide variant of hCG associated with Down syndrome pregnancies. We evaluated this new Down syndrome-directed test in prenatal diagnosis. METHODS Hyperglycosylated hCG was measured in urine samples from women undergoing amniocentesis for advanced maternal age concerns at 14-22 weeks of gestation, 1448 with normal karyotype and 39 with Down syndrome fetuses. RESULTS The median hyperglycosylated hCG value was 9.5-fold higher in Down syndrome cases (9.5 multiples of the normal karyotype median). The single test detected 80% of Down syndrome cases at a 5% false-positive rate. Urine hyperglycosylated hCG was combined with urine beta-core fragment (urine breakdown product of serum hCG free beta-subunit), serum alpha-fetoprotein, and maternal age-related risk. This urine-serum combination detected 96% of Down syndrome cases at a 5% false-positive rate, 94% of cases at a 3% false-positive rate, and 71% of cases at a 1% false-positive rate. These detection rates exceed those of any previously reported combination of biochemical markers. CONCLUSIONS Hyperglycosylated hCG is a new base marker for Down syndrome screening in the second trimester of pregnancy. The measurement of hyperglycosylated hCG can fundamentally improve the performance of Down syndrome screening protocols.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation and validation of a duck IgY antibody-based immunoassay for high-sensitivity C-reactive protein: avian antibody application in clinical diagnostics.

1. Kovalevskaya G, Birken S, Kakuma T, Ozaki N, Sauer M, Lindheim S, et al. Differential expression of human chorionic gonadotropin (hCG) glycosylation isoforms in failing and continuing pregnancies: preliminary characterization of the hyperglycosylated hCG epitope. J Endocrinol 2002;172:497–506. 2. Elliott MM, Kardana A, Lustbader JW, Cole LA. Carbohydrate and peptide structure of the and -sub...

متن کامل

Ulf-håkan Stenman 2* the Detection of Double Mutations in Kras Depends on the Mutation-detection Assay Used Letters to the Editor

1. Cole LA, Shahabi S, Oz UA, Rinne KM, Omrani A, Bahado-Singh RO, Mahoney MJ. Urinary screening tests for fetal Down syndrome: II. Hyperglycosylated hCG. Prenat Diagn 1999;19:351–9. 2. Kovalevskaya G, Birken S, Kakuma T, Ozaki N, Sauer M, Lindheim S, et al. Differential expression of human chorionic gonadotropin (hCG) glycosylation isoforms in failing and continuing pregnancies: preliminary ch...

متن کامل

Validating a rapid method for detecting common polymorphisms in the APOA5 gene by melting curve analysis using LightTyper.

Diagn 2000;20:976–8. 10. Shahabi S, Oz UA, Bahado-Singh RO, Mahoney MJ, Omrani A, Baumgarten A, et al. Serum hyperglycosylated hCG: a potential screening test for fetal Down syndrome. Prenat Diagn 1999;19:488–9. 11. Pandian R, Lu J, Ossolinska-Plewnia J. Fully automated chemiluminometric assay for hyperglycosylated human chorionic gonadotropin (invasive trophoblast antigen). Clin Chem 2003;49:8...

متن کامل

Fully automated chemiluminometric assay for hyperglycosylated human chorionic gonadotropin (invasive trophoblast antigen).

Fully Automated Chemiluminometric Assay for Hyperglycosylated Human Chorionic Gonadotropin (Invasive Trophoblast Antigen), Raj Pandian, Julie Lu, and Jolanta Ossolinska-Plewnia ( Quest Diagnostics, Nichols Institute, 33608, Ortega Highway, San Juan Capistrano, CA 92690; 2 Nichols Institute Diagnostics, San Clemente, CA 92673; * author for correspondence: fax 949-728-4990, e-mail pandianr@questd...

متن کامل

Invasive trophoblast antigen (hyperglycosylated human chorionic gonadotropin) in second-trimester maternal urine as a marker for down syndrome: preliminary results of an observational study on fresh samples.

BACKGROUND Down syndrome screening is commonly performed in the US using maternal age and three or four second-trimester maternal serum markers that can identify up to 75% of affected pregnancies by offering diagnostic studies to 5% of women. Invasive trophoblast antigen [ITA; hyperglycosylated human chorionic gonadotropin (hCG)] is a promising marker that can be measured in urine or serum in t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 45 12  شماره 

صفحات  -

تاریخ انتشار 1999