Patellar polyethylene spinout after low-contact stress, high-congruity, mobile-bearing patellofemoral arthroplasty.

نویسندگان

  • Derek F Amanatullah
  • Amir A Jamali
چکیده

A low-contact stress, high-congruity, mobile-bearing patellofemoral joint arthroplasty decreases the contact force in the patellofemoral joint, theoretically reducing patellar polyethylene wear and increasing implant longevity. This article describes the case of a 47-year-old obese woman who presented with pain and loss of extension after a low-contact stress, high-congruity, mobile-bearing patellofemoral joint arthroplasty. Radiographs revealed dislocation (ie, spinout) of the patellar polyethylene. Patellar polyethylene spinout is a rare complication of metal-backed, mobile-bearing patellar resurfacing. Theoretically, patellar polyethylene spinout in low-contact stress, high-congruity, mobile-bearing patellofemoral arthroplasty is related to implant design and the placement of the metal base plate. Ultimately, the articulation of low-contact stress, high-congruity, mobile-bearing patellofemoral arthroplasty may be too congruent to resist the forces of the patellofemoral joint, particularly in patients who are obese, and the patellar rotation allowed by this articulation may not be sufficient for all patients. Should patellar spinout occur, replacement of the polyethylene is not sufficient to correct the problem; hence, revision of the patellar and trochlear components is required because it remains unclear whether failure is secondary to patellar or trochlear design deficiencies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dissociation of mobile-bearing patellar component in low contact stress patellofemoral arthroplasty, its mechanism and management: two case reports

INTRODUCTION Isolated patellofemoral osteoarthritis can be treated with patellofemoral arthroplasty. CASE PRESENTATION We present two cases of isolated patellofemoral osteoarthritis treated with Low Contact Stress patellofemoral arthroplasty; in both cases the polyethylene mobile-bearing of the patellar component dissociated from the metal backing. One patient had a revision to a Richards pat...

متن کامل

Effects of patellar resurfacing on contact area and contact stress in total knee arthroplasty.

The objective of this study was to examine the effects of patellar resurfacing on patellofemoral joint contact pressure and contact area in total knee arthroplasty. We tested seven fresh-frozen cadaveric knees using a custom knee jig which permits the simulation of physiologic quadriceps loading. Before patellar resurfacing, the mean peak contact pressure of medial and lateral patellofemoral jo...

متن کامل

Mobile-bearing, congruent patellofemoral prosthesis: short-term results.

PURPOSE To report the short-term outcome of the low contact stress (LCS) patellofemoral prosthesis in 51 knees. METHODS 12 men and 37 women aged 23 to 79 (mean, 53.4) years underwent 51 consecutive LCS patellofemoral replacements. All patients had symptomatic isolated arthritis in the patellofemoral joint with well-preserved tibiofemoral compartments. All knees were evaluated pre- and post-op...

متن کامل

The low contact stress patellofemoral replacement: high early failure rate.

The low contact stress patellofemoral replacement consists of a trochlear component and a modular patellar component which has a metal-backed mobile polyethylene bearing. We present the early results of the use of this prosthesis for established isolated patellofemoral arthritis in 51 consecutive patellofemoral replacements in 35 patients. The mean follow-up was 25 months (5 to 60). The estimat...

متن کامل

Basic kinematics and biomechanics of the patellofemoral joint part 2: the patella in total knee arthroplasty.

Patellar and femoral component in total knee arthroplasty are inextricably linked as a functional unit. The configuration of this unit has been a matter of ongoing debate, and the myriad of different patellar and femoral components currently available reflect the lack of consensus with respect to the ideal design. One of the major challenges is to overcome the biomechanical disadvantages of a s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 35 2  شماره 

صفحات  -

تاریخ انتشار 2012