Effects of electrode design and configuration on channel interactions.

نویسندگان

  • Ginger S Stickney
  • Philipos C Loizou
  • Lakshmi N Mishra
  • Peter F Assmann
  • Robert V Shannon
  • Jane M Opie
چکیده

A potential shortcoming of existing multichannel cochlear implants is electrical-field summation during simultaneous electrode stimulation. Electrical-field interactions can disrupt the stimulus waveform prior to neural activation. To test whether speech intelligibility can be degraded by electrical-field interaction, speech recognition performance and interaction were examined for three Clarion electrode arrays: the pre-curved, enhanced bipolar electrode array, the enhanced bipolar electrode with an electrode positioner, and the Hi-Focus electrode with a positioner. Channel interaction was measured by comparing stimulus detection thresholds for a probe signal in the presence of a sub-threshold perturbation signal as a function of the separation between the two simultaneously stimulated electrodes. Correct identification of vowels, consonants, and words in sentences was measured with two speech strategies: one which used simultaneous stimulation and another which used sequential stimulation. Speech recognition scores were correlated with measured electrical-field interaction for the strategy which used simultaneous stimulation but not the strategy which used sequential stimulation. Higher speech recognition scores with the simultaneous strategy were generally associated with lower levels of electrical-field interaction. Electrical-field interaction accounted for as much as 70% of the variance in speech recognition scores, suggesting that electrical-field interaction is a significant contributor to the variability found across patients who use simultaneous strategies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantative Evaluation of the Efficiency of Facial Bio-potential Signals Based on Forehead Three-Channel Electrode Placement For Facial Gesture Recognition Applicable in a Human-Machine Interface

Introduction: Today, facial bio-potential signals are employed in many human-machine interface applications for enhancing and empowering the rehabilitation process. The main point to achieve that goal is to record appropriate bioelectric signals from the human face by placing and configuring electrodes over it in the right way. In this paper, heuristic geometrical position and configuration of ...

متن کامل

Design of Innovative Channel Geometrical Configuration and Its Effect on Species Distribution

In this research, the impact of shoulder width and geometry of gas channel with different structures on proton exchange membrane (PEM) has been investigated using numerical method. 3D, non-isothermal was used with single straight channel geometrywhile maintaining the same boundary conditions and reaction area with addition of humidification for anode and cathode. Our study showed that an ellipt...

متن کامل

Flexible Electrode Array for Retinal Stimulation

In this Work, ITO/PET (Indium Tin Oxide / Polyethylene Terephthalate) electrode structure which provides biocompatibility, mechanical stability and flexibility is fabricated. Flexible ITO/PET implantable electrode array for a retina has been developed. The electrode array is fabricated on a thin PET/ITO substrate and is encapsulated using, SU-8, an insulating material. PET substrate and SU-8 po...

متن کامل

Design of Compact Multi-Channel Diplexer Using Defected Microstrip Structure

In this paper, two compact quad-channel and six-channel diplexer are designed and fabricated using defected microstrip structure (DMS). This structure is designed for the desired frequency based on the literature reviews. The proposed configuration is composed of a conventional T-junction divider with two pairs of open bended stubs and dual/tri-band filters. In designing dual band filters, a lo...

متن کامل

Design of Novel Drugs (P3TZ, H2P3TZ, M2P3TZ, H4P3TZ and M4P3TZ) Based on Zonisamide for Autism Treatment by Binding to Potassium Voltage-gated Channel Subfamily D Member 2 (Kv4.2)

The present research article relates to the discovery of the novel drugs based on Zonisamide to treatment of autism disease. In first step, the electronic properties, reactivity and stability of the said compound are discussed. To attain these properties, the said molecular structure is optimized using B3LYP/6-311++G(d,p) level of theory at room temperature. The frontier molecular orbitals (FMO...

متن کامل

Numerical Modeling of an Innovative Bipolar Plate Design Based on the Leaf Venation Patterns for PEM Fuel Cells

Flow channel design on bipolar plates has a direct effect on Proton Exchange Membrane (PEM) fuel cell performance. It has been found out that the flow field design has a deterministic role on the mass transport and water management, and therefore on the achieved power in PEM Fuel cells. This study concentrates on improvements in the fuel cell performance through optimization of channel dimensio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hearing research

دوره 211 1-2  شماره 

صفحات  -

تاریخ انتشار 2006