Detection of Mycoplasma pneumoniae by loop-mediated isothermal amplification (LAMP) assay and serology in pediatric community-acquired pneumonia.

نویسندگان

  • Kensei Gotoh
  • Naoko Nishimura
  • Yasunori Ohshima
  • Yasuko Arakawa
  • Haruki Hosono
  • Yasuto Yamamoto
  • Yasushi Iwata
  • Kazumasa Nakane
  • Keiji Funahashi
  • Takao Ozaki
چکیده

Rapid diagnosis of Mycoplasma pneumoniae pneumonia is required for treatment with effective antimicrobial agents without delay; however, this capacity has not yet been established in clinical practice. Recently, a novel nucleic acid amplification method termed loop-mediated isothermal amplification (LAMP) has been used to rapidly diagnose various infectious diseases. In this study, we prospectively evaluated the efficacy of the LAMP assay to rapidly diagnose M. pneumoniae pneumonia in clinical practice. Three hundred sixty-eight children (median age, 3.8 years; range, 0.1-14.3 years) admitted to our hospital between April 2009 and March 2010 for community-acquired pneumonia were enrolled in this study. We obtained throat swabs on admission to detect M. pneumoniae DNA and paired serum samples on admission and at discharge to assay M. pneumoniae antibody titers. M. pneumoniae pneumonia was diagnosed by either a positive LAMP assay or a fourfold or greater increase in antibody titer. Overall, 46 children (12.5% of the patients with pneumonia) were diagnosed with M. pneumoniae pneumonia; of these, 27 (58.7%) were aged less than 6 years. Of the aforementioned 46 children, 38 (82.6%) and 37 (80.4%) were identified by LAMP and serology, respectively. When the results of serology were taken as the standard, the sensitivity and specificity and positive and negative predictive values of the LAMP assay were 78.4%, 97.3%, 76.3%, and 97.6%, respectively. We concluded the LAMP assay may be useful for rapid diagnosis of M. pneumoniae pneumonia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Isothermal Detection of Mycoplasma pneumoniae Directly from Respiratory Clinical Specimens.

Mycoplasma pneumoniae is a leading cause of community-acquired pneumonia (CAP) across patient populations of all ages. We have developed a loop-mediated isothermal amplification (LAMP) assay that enables rapid, low-cost detection of M. pneumoniae from nucleic acid extracts and directly from various respiratory specimen types. The assay implements calcein to facilitate simple visual readout of p...

متن کامل

A reverse transcriptase-loop mediated isothermal amplification assay (RT-LAMP) for rapid detection of bovine viral diarrhea virus 1 and 2

Bovine viral diarrhea virus (BVDV) is a pathogen that infects cattle, and is globally important. It causes substantial financial losses to the livestock industry. In the current study, a one-step reverse transcriptase-loop-mediated isothermal amplification (RT-LAMP) assay was set up for rapid and efficient detection of BVDV. For this purpose, four primers were designed to recognize six distinct...

متن کامل

Loop-Mediated Isothermal Amplification (LAMP) for the Rapid Diagnosis of Herpes Simplex Virus Type 1 (HSV-1)

Background and Aims: considering difficulties in usual laboratory methods in detection of viral infections, improved DNA-based diagnostic techniques are more reliable. Loop mediated isothermal amplification method (LAMP) is a nucleic acid amplification method that amplifies DNA using six primers which has been developed to diagnose viruses as a rapid and high efficiency test. In this study, the...

متن کامل

تشخیص و افتراق سریع فاسیولا هپاتیکا و فاسیولا ژیگانتیکا با استفاده از روش loop-mediated Isothermal Amplification

Background and purpose: Fasciola hepatica and Fasciola gigantica are common liver flukes which affect both human and livestock worldwide. In this study we evaluated the loop-mediated isothermal amplification (LAMP) assay for detection and discrimination of Fasciola species. Materials and methods: Fifty adults of Fasciola worms were isolated from sheep and cattle liver form abattoirs in Mazand...

متن کامل

Loop-mediated isothermal amplification method targeting the lytA gene for detection of Streptococcus pneumoniae.

It is difficult to separate Streptococcus pneumoniae from the genotypically similar species Streptococcus mitis and Streptococcus oralis, which are commensals of the human oral cavity. A novel nucleic acid amplification technique, loop-mediated isothermal amplification (LAMP), which amplifies DNA under isothermal conditions (63 degrees C) with high specificity, efficiency, and rapidity, was exa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of infection and chemotherapy : official journal of the Japan Society of Chemotherapy

دوره 18 5  شماره 

صفحات  -

تاریخ انتشار 2012