A Novel Composite Sling for the Treatment of Stress Urinary Incontinence: First Clinical Experience

نویسنده

  • JEFFREY BLITSTEIN
چکیده

INTRODUCTION We face continuing challenges for the optimal form of treatment for stress urinary incontinence (SUI). Long-term outcome studies have revealed disappointing results for percutaneous needle suspensions and other sling substitutes secondary to failure due to the recurrence of urethral hypermobility or creation of urethral obstruction 1. The pubovaginal sling procedure is an established, reliable technique for correcting Type 3 (intrinsic sphincter defi ciency, ISD) SUI, and Type 2 SUI with coexisting ISD 2. Recently, the pubovaginal sling procedure has been popularized and used as a primary modality to treat all forms of SUI including urethral hypermobility (type 1 & 2) in the female patient 3. It is estimated that 30-65% of women with SUI present with mixed incontinence 4. Theoretically, preoperative irritative voiding symptoms (IVS) can also be corrected when the appropriate tension is applied to the sub-urethral sling relieving the traction on the pelvic nerves innervating the bladder 5. Weakness of the urethropelvic ligament (UPL) (endocervical and periurethral fascia) with its attachments to the arcus tendinous and urethra correlates with urethral hypermobility and SUI. This anatomical defect is a herniation of the pelvic contents. Anatomical corrective surgery has addressed these issues in the past with sub-optimal long-term results without the use of autologous or prosthetic sling material 2, 6-9. Many procedures have been utilized in order to attempt to re-support the UPL. If one were to reconstruct the fascia, one could potentially correct all forms of SUI secondary to urethral hypermobility. Complications of urethral sling procedures using a synthetic prosthesis have been reported: urethral obstruction, urinary retention, mesh erosion, extrusion, infection and nerve entrapment 10-11. A novel sling was designed to eliminate these inherent complications. The main objective of this operation is to address all anatomical concerns using a modifi ed Stamey approach. It is also designed to prevent the inherent complications seen with prosthetic material positioned underneath the urethra and bladder neck.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vaginal mesh extrusion associated with use of Mentor transobturator sling.

OBJECTIVES To describe my experience of vaginal mesh extrusion using the monofilament polypropylene transobturator sling, the Mentor ObTape. The Mentor ObTape was the first transobturator sling developed as an alternative to the retropubic commercially available suburethral slings for providing mid-urethral support as treatment of female stress urinary incontinence. METHODS Thirty patients un...

متن کامل

Transvaginal retropubic sling systems: efficacy and patient acceptability

Stress urinary incontinence is a common, disabling, and costly medical problem that affects approximately 50% of women with urinary incontinence. Suburethral retropubic slings have been developed as a minimally invasive and effective surgical option, and they have been used as a first-line treatment for stress urinary incontinence since 1995. However, complications including vaginal extrusion, ...

متن کامل

Surgical technique using AdVance sling placement in the treatment of post-prostatectomy urinary incontinence.

OBJECTIVES To describe and illustrate a new minimally invasive approach to the treatment of male stress urinary incontinence following prostatectomy. SURGICAL TECHNIQUE Our initial experience consisted of four patients treated with the Advance sling for post-prostatectomy urinary incontinence. Sling placement involves the following steps: 1. Urethral dissection and mobilization, 2. Identifica...

متن کامل

The clinical effectiveness of transobturator midurethral sling (T-sling) with additional 2-point tape fixation performed on inpatient and outpatient basis

Nowadays midurethral sling are considered as a gold standard for stress urinary incontinence [1][Fig.1]. Traditionally, this technique has been followed by hospitalization and short inpatient convalescence. From both patient and physician perspective, this technique became increasingly popular due to very high clinical effectiveness, fast recovery, no need of painful incisions or overnight hosp...

متن کامل

Runninghead: ALTIS SINGLE INCISION SLING The Safety and Efficacy of a New Adjustable Single Incision Sling for Treatment of Female Stress Urinary Incontinence Through 12-months of Follow-up

Purpose: The purpose of this report is to describe the safety and efficacy of the Altis ® Single Incision Sling System (Altis sling) for treatment of female stress urinary incontinence through 12 months. Materials and Methods: This study collected a variety of safety and efficacy measures relevant to assessment of urinary incontinence. The primary efficacy endpoint was improvement in 24hour pad...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003