A simple, non-dimensional, normalized common carotid Doppler velocity wave-form index that identifies patients with carotid stenosis.
نویسنده
چکیده
A non-invasive Doppler velocity index that is specific for carotid artery stenosis is presented. The index is both non-dimensional (maximum/minimum velocity to remove within artery Doppler signal variability) and normalized (larger over smaller carotid maximum/minimum ratio to minimize between patient variability). Of 260 normal patients 94% had a maximum/minimum index between 1.00 and 1.25 and 97.5% had an index between 1.00 and 1.30. In 136 patients undergoing selective carotid arteriography the overall accuracy of the maximum/minimum index in predicting carotid stenosis was 85-87%. When 1.30 is taken as the maximum normal index value the test is 96.5% specific and 76% sensitive. The receiver operating characteristic curve indicates that patients with a maximum/minimum index greater than 1.4 have a 99% probability of significant carotid stenosis.
منابع مشابه
Candida patients in a Jorjani center in Shahid Mohammadi Hospital of carotid Doppler sonnograghy findings in coronary artery Bypas grafting Bandar Abbas
Introduction: Nowadays caotid Dopplers sonography is gold standard for carotid artery screening in coronary aetery bypass grafting (CABG) candidates. This study was carried out in an angioplasty center in southern seaport in Iran to assesss theprevalence of artery stenosis and correlation of the atherosclerosis risk factor with the rate of artery stensis, and nence to define the high risk group...
متن کاملبررسی دقت و همبستگی سونوگرافی داپلر رنگی با آنژیوگرافی در تعیین شدت تنگی عروق کاروتید گردنی در بیماران ایسکمی مغزی
This is retrospective double-blind research, which was carried out in Imam Khomeini hospital in order to study the accuracy of color Doppler ultrasonography for detecting the site and grade of stenosis in cervical carotid artery. 40 patients with mean age of 62 years studied with color Doppler before DSA angiography. The most common sites of stenosis were left internal carotid (39.5%) and right...
متن کاملمقایسه توپوگرافی تنگی قلمروکاروتید در بیماران سکته مغزی با دو نژاد آمریکای شمالی و ایرانی
Introduction: Atherosclerotic stenosis of carotid territory is the most common cause of ischemic stroke. A higher frequency of intracranial arterial stenosis has been reported in Africa and the Far East. Methods: 304 geriatric ischemic stroke patients admitted in Mackenzie hospital, Canada and the same number of geriatric ischemic stroke patients with similar sex ratio admitted in Valie-Asr ho...
متن کاملCorrelation of continuous-wave Doppler spectral flow analysis with gross pathology in carotid stenosis.
Preoperative continuous-wave Doppler spectral analysis was used to generate two parameters, peak frequency in the internal carotid artery (fmax) and the ratio of peak frequencies in the internal and common carotid arteries (carotid index). These were compared with direct measurement of residual lumen diameter in pathologic specimens obtained from carotid endarterectomy in 37 patients. Doppler s...
متن کاملبررسی یافته های سونوگرافی داپلر عروق کاروتید اکستراکرانیال بیماران مبتلا به سکته مغزی (Anterior circulation) بر اساس محدوده گرفتاری در سی تی اسکن
Background and purpose : Ârterial embolism is one of the most prevalent cause of transient ischemic attack (TÏÂ) and other types of brain ischemias and about 5o% of TÏÂ patiens have vascular stenosis. Therefore the presence of mild atherosclerotic plaques in carotid arteries, as a source of embdlism in causing TÏÂ and other brain strokes are of a great importance. Ïn present study the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Stroke
دوره 12 3 شماره
صفحات -
تاریخ انتشار 1981