Visual performance of the Tecnis one-piece lens ZCB00
نویسندگان
چکیده
SYNOPSIS The aspheric, one-piece design of the Tecnis® ZCB00 intraocular lens provided higher mesopic contrast sensitivity and relatively constant refraction at different pupil sizes compared to the Sensar® AR40e. PURPOSE Comparing the impact on functional vision of the aspheric Tecnis® ZCB00 one-piece lens compared to the spherical Sensar® AR40e three-piece lens. SETTING National Eye Hospital, Cairo, Egypt. METHODS In this prospective study, we implanted 32 Tecnis ZCB00 (Abbott Medical Optics, Santa Ana, CA) and 30 Sensar AR40e (Pharamacia and Upjohn LLC, North Peapack, NJ) lenses. Twenty-three patients in the ZCB00 group and 13 patients in the AR40e group provided reliable, reproducible data, and were therefore included in the statistical analysis. After 8 weeks, we measured photopic contrast sensitivity (PCS) at 85 cd/m(2) and mesopic contrast sensitivity (MCS) at 5 cd/m(2). Uncorrected and best-corrected visual acuity were measured. Myopic shift was analyzed by comparing the manifest refraction spherical equivalent at 3 days and 8 weeks after surgery in the normal and dilated pupil. RESULTS The Tecnis ZCB00 group showed significantly better MCS than the Sensar AR40e group at a spatial frequency of six cycles per degree (cpd) (P = 0.037), but not at 3, 12, or 18 cpd (P = 0.299, P = 0.226, and P = 0.396, respectively). There were no significant differences between groups in corrected distance visual acuity (P = 0.175) or PCS at 3, 6, 12, or 18 cpd spatial frequencies (P = 0.440, P = 0.176, P = 0.365, and P = 0.251, respectively). The ZCB00 group showed less myopic shift in normal and dilated pupils between 3 days and 8 weeks after surgery compared to the AR40e group, but this difference was not significant. CONCLUSION The Tecnis one-piece ZCB00 provided higher MCS at moderate spatial frequency than the three-piece Sensar AR40e, and was associated with relatively constant refraction at different pupil sizes.
منابع مشابه
Reversible opacification of hydrophobic acrylic intraocular lens- two cases report
BACKGROUND The opacification of the intraocular lens (IOL) can cause significant visual deterioration. It is known that opacity of hydrophobic acrylic IOLs is rare. We report 2 cases of reversible optic opacification of hydrophobic acrylic intraocular lenses (Tecnis ZCB00, Abbott), observed within 2 months after uneventful cataract surgery. CASE PRESENTATION Case 1: Uneventful cataract surger...
متن کاملComparison of Visual Performance of Multifocal Intraocular Lenses with Same Material Monofocal Intraocular Lenses
PURPOSE To compare the visual performance of multifocal intraocular lenses (IOLs) and monofocal IOLs made of the same material. METHODS The subjects included patients implanted with either Tecnis® monofocal IOLs (ZA9003 or ZCB00) or Tecnis® multifocal IOLs (ZMA00 or ZMB00) bilaterally. We conducted a retrospective study comparing the two types of IOLs. The multifocal group included 46 patient...
متن کاملRefractive index and its impact on pseudophakic dysphotopsia
PURPOSE It has been shown that the biggest dissatisfier for uncomplicated cataract surgery patients is pseudophakic dysphotopsia (PD). While edge design of an intraocular lens (IOL) impacts this problem, refractive index is still controversial as to its impact. This retrospective cohort study was designed to determine the role of increasing refractive index in PD. PATIENTS AND METHODS This st...
متن کاملPreloaded and non-preloaded intraocular lens delivery system and characteristics: human and porcine eyes trial.
AIM To compare characteristics of preloaded and non-preloaded intraocular lens (IOL) delivery systems during IOL delivery procedures. METHODS Total 101 human eyes were included in this prospective observational case series. Delivery characteristics of 5 types of IOLs including iSert250 NC60 (NC60), EnVista MX60 (MX60), AcrySof IQ SN60WF (SN60WF), TECNIS ZCB00 (ZCB00), and TECNIS PCB00 (PCB00)...
متن کاملVisual acuity and patient satisfaction at varied distances and lighting conditions after implantation of an aspheric diffractive multifocal one-piece intraocular lens
PURPOSE The aim of the study is to evaluate the visual acuity and patient satisfaction at varied distances under photopic and mesopic lighting conditions in patients bilaterally implanted with aspheric diffractive multifocal one-piece intraocular lenses. METHODS In this retrospective-prospective study, 16 patients with a mean age of 66.2±9.2 years (range: 50-81 years) who had undergone bilate...
متن کامل