Impact of crestal and subcrestal implant placement in peri-implant bone: A prospective comparative study

نویسندگان

  • Hilario Pellicer-Chover
  • María Peñarrocha-Diago
  • David Peñarrocha-Oltra
  • Sonia Gomar-Vercher
  • Rubén Agustín-Panadero
  • Miguel Peñarrocha-Diago
چکیده

BACKGROUND To assess the influence of the crestal or subcrestal placement of implants upon peri-implant bone loss over 12 months of follow-up. MATERIAL AND METHODS Twenty-six patients with a single hopeless tooth were recruited in the Oral Surgery Unit (Valencia University, Valencia, Spain). The patients were randomized into two treatment groups: group A (implants placed at crestal level) or group B (implants placed at subcrestal level). Control visits were conducted by a trained clinician at the time of implant placement and 12 months after loading. A previously established standard protocol was used to compile general data on all patients (sex and age, implant length and diameter, and brushing frequency). Implant success rate, peri-implant bone loss and the treatment of the exposed implant surface were studied. The level of statistical significance was defined as 5% (α=0.05). RESULTS Twenty-three patients (8 males and 15 females, mean age 49.8±11.6 years, range 28-75 years) were included in the final data analyses, while three were excluded. All the included subjects were non-smokers with a brushing frequency of up to twice a day in 85.7% of the cases. The 23 implants comprised 10 crestal implants and 13 subcrestal implants. After implant placement, the mean bone position with respect to the implant platform in group A was 0.0 mm versus 2.16±0.88 mm in group B. After 12 months of follow-up, the mean bone positions were -0.06±1.11 mm and 0.95±1.50 mm, respectively - this representing a bone loss of 0.06±1.11 mm in the case of the crestal implants and of 1.22±1.06 mm in the case of the subcrestal implants (p=0.014). Four crestal implants and 5 subcrestal implants presented peri-implant bone levels below the platform, leaving a mean exposed treated surface of 1.13 mm and 0.57 mm, respectively. The implant osseointegration success rate at 12 months was 100% in both groups. CONCLUSIONS Within the limitations of this study, bone loss was found to be greater in the case of the subcrestal implants, though from the clinical perspective these implants presented bone levels above the implant platform after 12 months of follow-up.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of implant placement depth on the peri-implant bone defect configurations in ligature-induced peri-implantitis: An experimental study in dogs

BACKGROUND The subcrestal placement of implant platform has been considered a key factor in the preservation of crestal bone, but the influence of implant placement depth on bone remodeling combined with peri-implantitis is not fully understood. The aim of this study was to assess the effect of the crestal or subcrestal placement of implants on peri-implant bone defects of ligature-induced peri...

متن کامل

Ligature-induced peri-implant infection in crestal and subcrestal implants: a clinical and radiographic study in dogs

Objective. The aim of this study was to assess the influence of implant-abutment interface (IAI) placement depths on peri-implant tissues in the presence of ligature-induced peri-implant inflammation. Materials and Methods. Two implants with screwed-in IAIs (SI) and two implants with tapped-in IAIs (TI) were inserted in one side of the mandible in six dogs eight weeks after tooth extraction. Fo...

متن کامل

Long-term results after subcrestal or crestal placement of delayed loaded implants.

PURPOSE Prevention of peri-implant bone loss is essential for achieving long-term implant success, but few studies have evaluated the impact of placement depth on long-term bone loss. The aim of this retrospective study was to evaluate outcomes for platform-shifted implants placed at different depths relative to the bone crest. MATERIALS AND METHODS The mesial and distal shoulders of 228 dela...

متن کامل

Biomechanical evaluation of subcrestal dental implants with different bone anchorages.

This study evaluated the biomechanical influence of apical bone anchorage on a single subcrestal dental implant using three-dimensional finite element analysis (FEA). Four different bone anchorage designs were simulated on a posterior maxillary segment using one implant with platform switching and internal Morse taper connection as follows: 2 mm subcrestal placement with (SW) or without (SO) th...

متن کامل

Peri-implant inflammation defined by the implant-abutment interface.

An implant-abutment interface at the alveolar bone crest is associated with sustained peri-implant inflammation; however, whether magnitude of inflammation is proportionally dependent upon interface position remains unknown. This study compared the distribution and density of inflammatory cells surrounding implants with a supracrestal, crestal, or subcrestal implant-abutment interface. All impl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 21  شماره 

صفحات  -

تاریخ انتشار 2016