Closure of a muscular ventricular septal defect using the Amplatzer ventricular occluder.

نویسندگان

  • Majid Dehghani
  • Mohammad-Bagher Sharifkazemi
  • Amir Aslani
  • Ehsan Hoseini
  • Mohammad-Mehdi Samin
چکیده

Surgical closure of ventricular septal defect is safe, however, the inherent risks associated with cardiopulmonary bypass and the potential early and late postsurgical complications including complete heart block, arrhythmias, postpericardiotomy syndrome, and rare deaths have led physicians to prefer transcatheter occlusion technique for closure of such defects. The use of Amplatzer muscular ventricular septal defect occluder is safe and associated with a higher success rate than other previously used devices. For the first time in Iran, we report an 18-year-old patient with ventricular septal defect who was successfully treated using the Amplatzer ventricular septal defect occluder.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Transcatheter closure of postinfarction ventricular septal defects using Amplatzer devices].

We carried out transcatheter procedures to close postinfarction ventricular septal defects (PIVSDs) in 19 patients: two had recanalization after surgical closure, and 17 had a primary PIVSD. In three of the latter patients, who had acute PIVSDs, the procedure was carried out in the first 3 weeks after infarction; in the 13 patients with subacute PIVSD, it was carried out 3.5-12 weeks after infa...

متن کامل

Transcatheter Closure of a Muscular Ventricular Septal Defect By Amplatzer Ductal Occluder II

Ventriküler septal defektler transkateter tedavide kapatılması gereken bir defekt olarak görülmektedir. Son yıllarda yeni cihazların bulunması ile birçok merkezde ventriküler septal defektlerin perkütan kapatılması cesaretlendiren sonuçlarla uygulanmaktadır. Amplatzer oklüder sistemlerin son yıllarda kullanılmaya başlaması ile birlikte implantasyon sayılarında artma olmuştur. Bunun yanısıra, mü...

متن کامل

Safety and efficacy of Amplatzer duct occluder for percutaneous closure of ventricular septal defects with tunnel shape aneurysm: Medium term follow up

Objectives: Different devices including Amplatzer duct occluder has been used for percutaneous closure of ventricular septal defects. This study reports our medium term follow up of perimembranous and muscular ventricular septal defects with tunnel shape aneurysm closure using the Amplatzer duct occluder. Materials and Methods: From May 2006-December 2012, we used Amplatzer duct occluder in sev...

متن کامل

Percutaneous closure of perimembranous ventricular septal defects associated with septal aneurysm in adults.

OBJECTIVE Percutaneous closure of perimembranous ventricular septal defects (pmVSD) has become an accepted alternative to surgical closure in selected cases. However, closure of pmVSDs associated with septal aneurysm is more challenging. We report our experience of device closure of pmVSDs associated with septal aneurysm. METHODS Between 2008 and 2012, percutaneous closure of pmVSD associated...

متن کامل

[Right patent ductus arteriosus with an ipsilateral aortic arch: percutaneous closure with amplatzer devices].

The association of a right aortic arch with an ipsilateral patent ductus arteriosus is rare, especially when there are no other intracardiac anomalies. We report three female patients aged 26, 35 and 9 years with this combination in whom previous attempts at surgical closure by thoracotomy and sternotomy were unsuccessful and who subsequently underwent successful percutaneous closure of the def...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of Iranian medicine

دوره 10 4  شماره 

صفحات  -