This paper presents a model-based approach to estimation of cardiac output (CO) and total peripheral resistance (TPR). In the proposed approach, the response of cardiovascular system (CVS), described by the windkessel model, is tuned to the measurements of systolic, diastolic and mean arterial blood pressures (BP) so as to yield optimal individual- and time-specific system time constant that is used to estimate CO and TPR. Unique aspects of the proposed approach are that it approximates the aortic flow as a train of square waves and that it also assumes pressure-dependent arterial compliance, as opposed to the traditional windkessel model in which aortic flow is approximated as a train of impulses and constant arterial compliance is assumed. It was shown that the proposed model encompasses the standard windkessel model as a limiting case, and that it also yields more realistic BP waveform response than the standard windkessel model. The proposed approach has potential to outperform its standard counterpart by treating systolic, diastolic, and mean BP as independent features in estimating CO and TPR, rather than solely resorting to pulse pressure as in the case of the standard windkessel model. Experimental results from in-vivo data collected from a number of animal subjects supports the viability of the proposed approach in that it could achieve approximately 29% and 24% reduction in CO and TPR errors when compared with its standard counterpart.
منابع مشابه
Effects of exercise on aortic input impedance and pressure wave forms in normal humans.
The effects of supine bicycle exercise on the input impedance of the ascending aorta were studied in thirteen male subjects undergoing cardiac catheterization, but in whom no cardiovascular disease was found. Ascending aortic flow velocity and pressure were recorded simultaneously from a multisensor catheter with an electromagnetic flow velocity probe and a pressure sensor mounted at the same l...
متن کاملComputation of aortic flow from pressure in humans using a nonlinear, three-element model.
We computed aortic flow pulsations from arterial pressure by simulating a nonlinear, time-varying three-element model of aortic input impedance. The model elements represent aortic characteristic impedance, arterial compliance, and systemic vascular resistance. Parameter values for the first two elements were computed from a published, age-dependent, aortic pressure-area relationship (G. J. Lan...
متن کاملDetection of Cardiac Hypertrophy by RVM and SVM Algorithms
The meaning of the hypertropy word is the increasing size.Heart hypertropy is symptoms of increase the thickness of the heart muscle that the left ventricular hypertrophy of them is the most common.The causes of hypertrophy heart disease are high blood pressure , aortic valve stenosis and sport activities respectively. Assessment of that by using ECG signal analysis is essential Because the ris...
متن کاملVentricular/vascular interaction in patients with mild systemic hypertension and normal peripheral resistance.
Total left ventricular external power and aortic input impedance spectra were calculated from recordings of pulsatile pressure and flow in the ascending aorta of 22 human subjects undergoing cardiac catheterization. Eleven subjects had increased aortic pressure (systolic 153 +/- 3.8[SEM] mm Hg, p less than .001; diastolic 91 +/- 2.4 mm Hg, p less than .03; mean 118 +/- 2.4 mm Hg, p less than .0...
متن کاملPeripheral vascular decoupling in porcine endotoxic shock.
Cardiac output measurement from arterial pressure waveforms presumes a defined relationship between the arterial pulse pressure (PP), vascular compliance (C), and resistance (R). Cardiac output estimates degrade if these assumptions are incorrect. We hypothesized that sepsis would differentially alter central and peripheral vasomotor tone, decoupling the usual pressure wave propagation from cen...
متن کامل